Schneider Electric Thermal Overload Relay NO/NC, 2.6 → 3.7 A, 3.7 A, 100 W, 250 V dc, 690 V ac

Datablad
Lagstiftning och ursprungsland
Ej tillämpbart
COO (Country of Origin): CZ
Produktdetaljer

Thermal Overload Relays

Phase failure sensitive
Test Button
Trip-Fault Indication
Manual or automatic reset facility
Temp. compensated trip -20 to +55°C

Standards

IEC 947, BS4941, VDE 0660, NFC63-650

Approvals

CSA, UL, DEMKO, NEMKO, SEMKO, FIMKO, PTB

Specifikationer
Attribute Value
FLC Motor Rating 2.6 → 3.7 A
Control Voltage 250 V dc, 690 V ac
Contact Current Rating 3.7 A
Pole Configuration 3P
Range TeSys
Contact Voltage Rating 690 V ac
Mounting Style Direct Contactor
Series LR2K
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Power Rating 100 W
Reset Method Automatic, Manual
Terminal Type Screw
Depth 65mm
Width 45mm
Length 116mm
Maximum Operating Temperature +55°C
Operating Temperature Range -20 → +55 °C
Minimum Operating Temperature -20°C
64 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
360,82 kr
(exkl. moms)
451,02 kr
(inkl. moms)
Enheter
Per unit
1 - 9
360,82 kr
10 - 14
346,18 kr
15 +
331,18 kr
Related Products
Protects motor against overload and phase lossTrip class ...
Description:
Protects motor against overload and phase lossTrip class 10Auxiliary switch 1N/O and 1N/CStable, shock-resistant direct mounting on 100-K contactorBuilt in trip contact 95//96 and signal contact 97//98Auto/manual reset selectable on devicevisible trip indicationTest/trip actuatorStop actuator.
The 3RU21 thermal overload relays up to 80 ...
Description:
The 3RU21 thermal overload relays up to 80 A have been designed for current-sensitive protection of loads with normal starting.These thermal overload relays for use with Sirius Size S0 & S00 Contactors. Switch position indicator and test functionSTOP buttonSelector switch ...
Type RF38, phase failure sensitive, manual or automatic ...
Description:
Type RF38, phase failure sensitive, manual or automatic resettingType RFN38, non phase failure sensitive, manual or automatic resettingType RF82 and RF95, phase failure sensitive, manual resettingType RFA82 and RFA95, phase failure sensitive, automatic resettingType RFN82 and RFN95, non phase failure ...
Can be used with all motors equipped with ...
Description:
Can be used with all motors equipped with PTC thermistor probes. It monitors windings temperature and ensures that the rated operating value is not exceeded, therefore guarding against faults which are often the cause of premature ageing. They can also ...