Dold Insulation Monitoring Relay, SPDT, 0.8 → 1.1 V, DIN Rail
- RS-artikelnummer:
- 240-9049
- Tillv. art.nr:
- AI898 DC24V 6kOhm UH=AC45-400Hz 230V
- Tillverkare / varumärke:
- Dold
Antal (1 enhet)*
4 878,41 kr
(exkl. moms)
6 098,01 kr
(inkl. moms)
GRATIS leverans för online beställningar över 500,00 kr
I lager
- 1 enhet(er) är redo att levereras från en annan plats
Behöver du mer? Ange den kvantitet du behöver och klicka på "Kontrollera leveransdatum"
Enheter | Per enhet |
|---|---|
| 1 + | 4 878,41 kr |
*vägledande pris
- RS-artikelnummer:
- 240-9049
- Tillv. art.nr:
- AI898 DC24V 6kOhm UH=AC45-400Hz 230V
- Tillverkare / varumärke:
- Dold
Specifikationer
Datablad
Lagstiftning och ursprungsland
Produktdetaljer
Hitta liknande produkter genom att välja ett eller flera attribut.
Välj alla | Attribut | Värde |
|---|---|---|
| Brand | Dold | |
| Monitoring Application | Insulation | |
| Voltage Sensing Range | 0.8 → 1.1 V | |
| Contact Configuration | SPDT | |
| Mounting Type | DIN Rail | |
| Time Delay | 0.4s | |
| Series | AI 898 | |
| Width | 45mm | |
| Minimum Operating Temperature | -20°C | |
| Maximum Operating Temperature | +60°C | |
| Height | 77mm | |
| Length | 115mm | |
| Operating Temperature Range | +60°C | |
| Dimensions | 115 x 45 x 77mm | |
| Välj alla | ||
|---|---|---|
Brand Dold | ||
Monitoring Application Insulation | ||
Voltage Sensing Range 0.8 → 1.1 V | ||
Contact Configuration SPDT | ||
Mounting Type DIN Rail | ||
Time Delay 0.4s | ||
Series AI 898 | ||
Width 45mm | ||
Minimum Operating Temperature -20°C | ||
Maximum Operating Temperature +60°C | ||
Height 77mm | ||
Length 115mm | ||
Operating Temperature Range +60°C | ||
Dimensions 115 x 45 x 77mm | ||
- COO (Country of Origin):
- DE
Insulation monitor for direct current networks, AI898
Fixed response time 6 kΩ
LED display for operational readiness and earth fault
1 changeover
Overall width 45 mm
LED display for operational readiness and earth fault
1 changeover
Overall width 45 mm
The AI898 insulation monitor displays the insulation resistance of unearthed direct current networks to earth. It does not detect symmetrical earth faults. In practice, these faults are generally insignificant.
The AI898 works on the quiescent current principle, for example when the auxiliary voltage is applied to terminals A1 → A2 the output relay is activated and the "ON" LED indicates that the insulation resistance RAN is not less than the minimum value. If insulation resistance falls below the response value, the output relay drops, the "ON" LED goes out and the second LED for "Earth fault" lights up.
A bridge between terminals LT1 and LT2 (inserted as standard) allows the AI898 to be programmed for memory storage behaviour; remove the bridge to programme hysteresis behaviour. The bridge can be replaced with a delete key with an NC contact. A test key (PT) tests the functional efficiency of the device (as per VDE 0435).
The AI898 works on the quiescent current principle, for example when the auxiliary voltage is applied to terminals A1 → A2 the output relay is activated and the "ON" LED indicates that the insulation resistance RAN is not less than the minimum value. If insulation resistance falls below the response value, the output relay drops, the "ON" LED goes out and the second LED for "Earth fault" lights up.
A bridge between terminals LT1 and LT2 (inserted as standard) allows the AI898 to be programmed for memory storage behaviour; remove the bridge to programme hysteresis behaviour. The bridge can be replaced with a delete key with an NC contact. A test key (PT) tests the functional efficiency of the device (as per VDE 0435).
relaterade länkar
- Dold Insulation Monitoring Relay 3 Phase 0.8 → 1.1 V, DIN Rail
- Dold Speed Monitoring Relay DIN Rail
- Dold Speed Monitoring Relay DIN Rail
- Dold Frequency Monitoring Relay DIN Rail
- Dold Monitoring Relay 24 → 400V ac/dc, DIN Rail
- Dold Frequency Monitoring Relay 15 → 280V ac, DIN Rail
- Dold Standstill Monitoring Relay 3 Phase DIN Rail
- Dold Multifunction Monitoring Relay SPDT DIN Rail