Schneider Electric XPS AF 24 V ac/dc Safety Relay Single or Dual Channel With 3 Safety Contacts - Preventa Range

Datablad
Lagstiftning och ursprungsland
Ej tillämpbart
COO (Country of Origin): ID
Produktdetaljer

Schneider Electric | Preventa XPSAF Series | Safety Relays

Simple and effective safety monitoring has never been more crucial in today's highly automated world. Prevention is key to site safety, that's why Schneider Electric offers a Safety Relay in the form of the 'Preventa XPSAF' module that is second to none. Being able to monitor faults with devices along a circuit has the power to stop emergency situations from even occurring.

Features and benefits:

• Single-channel with 3 N/O safety outputs

• Monitoring of a movable guard, with emergency stop monitoring 1 or 2 channel wiring usable.

• Configurable type of start is readily available for the type of activation you wish for your circuit.

• Monitoring of single safety functions, providing an automated solution for use with applications such as emergency push stop buttons or switches.

• Unlimited synchronisation between time inputs.

• Slin in design, with just 22.5mm of width meaning it can fit nicely even in space constraint spaces.

• Accepts cable up to 2.5mm²

• Symmetrical DIN rail support, offering flexible and versatile safety system installation.

• Local signalling in the form of LEDs.

Protection ratings & Safety features (see datasheet for specifics) -

• Impressive line resistance is available, varying between 90 to 100 Ohm (Ω).

• Input protection type is internal, electronic.

• EN1088/ISO 14119, EN 60204-1, EN/IEC 60947-5-1, EN/ISO 13850

• CSA, TUV & UL listed

• IP 40 (enclosure) for protection against small objects up to 1mm such as tools, wires and small wires.

• IP 20 (terminals) for protection against solid objects such as fingers, smaller tools up to 12mm.

• -25 to 60°C temperature range for operation, suitable in varying levels of heat/freezing temperatures.

Applications -

All dangerous machinery requires an automated solution to prevent harm to immediate users and also prevent damage to the machinery. Below are some of the safety applications

• Coded Magnetic Switch (CMS) to prevent tampering by unauthorised users.


• Time delay input if needed allowing you to set up your own time function.

• Light curtains / Two-hand control safety circuits

• Sensing mats and edges

Standards

IEC 204-1; EN 292; EN 418; EN 60204-1; EN 1088

Approvals

BG, UL, CSA

//media.rs-online.com/t_line/LI360435-01.gif
Specifikationer
Attribute Value
Supply Voltage 24 V ac/dc
Number of Channels 1, 2
Function Safety Switch/Interlock
Safety Contacts 3
Range Preventa
Terminal Type Screw
Length 99mm
Depth 114mm
Width 22.5mm
12 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
2 191,05 kr
(exkl. moms)
2 738,81 kr
(inkl. moms)
Enheter
Per unit
1 +
2 191,05 kr
Related Products
The G9SA family offers a line-up of compact ...
Description:
The G9SA family offers a line-up of compact and expandable safety relay units. Modules with safe OFF-delay timing are available as well as a two hand controller. Simple multiplication of safety contacts is possible by using the connection on the ...
The Phoenix Contact 2700525 safety relay is designed ...
Description:
The Phoenix Contact 2700525 safety relay is designed for emergency stop (E-Stop), light grids and safety doors up to Cat.4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061With 3 enabling current path and 1 signalling current path ...
Safety category 4 in accordance with DIN EN ...
Description:
Safety category 4 in accordance with DIN EN 954Output: 2 N/Os, 1 N/C1 or 2-channel configurationLine termination detection on the ON buttonProgrammable: Activation via the ON button or automatic ON function when the operating voltage is appliedProgrammable: With / without ...
Created and designed for guard monitoring, this range ...
Description:
Created and designed for guard monitoring, this range of XPS-DM safety relays are predominantly used for monitoring XCS-DMC and XCS-DMP coded magnetic safety switches. • When the XCS-DM safety switch is used in conjunction with the XPS-DM safety relay, together ...