Viper SCR Input/Output Module, 2 Inputs, 1 (Auxiliary), 3 (Safety) Outputs, 24 V ac/dc

  • RS-artikelnummer 123-2741
  • Tillv. art.nr 280007-P
  • Tillverkare / varumärke IDEM
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): GB
Produktdetaljer

IDEM SEU-31-i VIPER Expansion Unit

Professional range of IDEM VIPER Safety Relays with pluggable and screw terminals. The safety relays incorporate expansion units. The relays can be directly wired to increase the number of safety output contacts. Designed to meet the latest safety standard and offer enhanced LED diagnostics and simplified wiring. Typical applications include safety interlock switches and emergency e-stop devices door guard monitoring.
The expansion units are designed to be used with any SCR base units. Multiple SEU expansion units can be used together.

Expansion unit for SCR base units
LED status indicator
22.5 mm DIN Rail mount

Specifikationer
Attribute Value
Range Viper
Series SCR
Type Input/Output Module
For Use With SCR-21-i Safety Relay, SCR-31-42TD-i Safety Relay, SCR-31-i Safety Relay, SCR-31P-i Safety Relay, SCR-73-i Safety Relay
Supply Voltage 24 V ac/dc
Normal State Configuration 3NC
Number of Inputs 2
Number of Outputs 1 (Auxiliary), 3 (Safety)
Power Rating 1.6 W
Mounting Style DIN Rail
Terminal Type Plug In
Dimensions 22.5 x 111 x 99 mm
2 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
1 562,75 kr
(exkl. moms)
1 953,44 kr
(inkl. moms)
Enheter
Per unit
1 +
1 562,75 kr
Related Products
All units conform to BS EN 60204 Part ...
Description:
All units conform to BS EN 60204 Part 1 1993; EN 954-1; IEC 204-1; VDE 0113. Dimensions (mm) for all units: H 96.5, W 22.5, L 114,Contact Rating: 6A for all units. Colour supplied may vary from that shown. Used ...
The PSR safety relay extension units are for ...
Description:
The PSR safety relay extension units are for contact expansion. Single and two-channel control (stock no. 768-5147 & 801-5937), with one-channel connection only (stock no. 666-7113 & 801-5934)5 enabling current paths, 1 signalling current path, and 1 confirmation current pathInput ...
Functions include muting and override, concurrence monitoring, monitoring ...
Description:
Functions include muting and override, concurrence monitoring, monitoring total muting time, sensor gap monitoring, end of muting by ESPE. Applications: Opto-electronic protective devices and non-contact safety switches. 2 or 4 muting sensors1 reset/restart input and external device monitoringActivation and time ...
Fit for signal evaluation of outputs of safety ...
Description:
Fit for signal evaluation of outputs of safety magnetic switches2 safety contacts, Stop Category 06 Signalling outputsMulti-evaluation of up to 6 safety guardsSuitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks.