NX Communication Module, 20.4 28.8 V dc

  • RS-artikelnummer 862-5758
  • Tillv. art.nr NX-EIC202
  • Tillverkare / varumärke Omron
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): CN
Produktdetaljer

Omron NX-EIC EtherNet/IP Coupler Unit

The EtherNet/IP Coupler Unit is the link between the EtherNet/IP multi-vendor network and the NX-series I/O Units and Safety Units. With wide variety of the I/O Units and Safety Units, the NX-series is the perfect match for the CJ-series and multi-vendor controllers.

Up to 63 NX-IO Units can be connected to one EtherNet/IP Coupler Unit
Standard and high-performance units can be mixed
Each Coupler plus its I/O form just a single EtherCAT node on the network
I/O control and safety control can be integrated by connecting Units for safety
The IP address can be found on the label on the Unit, without using software
Slave configuration by Sysmac Studio can be done centrally via the controller, or on-the-spot using the Coupler's built-in USB port
Input per Coupler Unit: Maximum 504 bytes, Output per Coupler Unit: Maximum 504 bytes

Specifikationer
Attribute Value
Series NX
Type Communication Module
Supply Voltage 20.4 28.8 V dc
Connection Type USB Port
Mounting Style Panel
Dimensions 106 x 48.1 x 80 mm
2 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
3 553,00 kr
(exkl. moms)
4 441,25 kr
(inkl. moms)
Enheter
Per unit
1 +
3 553,00 kr
Related Products
N6700 series 1U, 100-240V, 4-slot mainframe accepts 1-4 ...
Description:
N6700 series 1U, 100-240V, 4-slot mainframe accepts 1-4 DC power modules (ordered separately) in any combination. If the mainframe is to be mounted then it is necessary to order the N6709A Rack Mount Kit 690-9644 . If fewer than 4 ...
The Preventa XPSMCM non-safe fieldbus communication modules are ...
Description:
The Preventa XPSMCM non-safe fieldbus communication modules are designed for diagnostic connection and data communication to machine field bus or network systems. They have a compact designed, 22.5 x 99 x 114.5 mm, the same size as a typical safety ...
For the integration of Flexi Soft data into ...
Description:
For the integration of Flexi Soft data into an existing PLC, up to two gateways can be added to a systemThe gateways provide I/O status and Error/Status messagingNon-safety related information can be sent to the Flexi Soft from the networkAdressing ...
For the integration of Flexi Soft data into ...
Description:
For the integration of Flexi Soft data into an existing PLC, up to two gateways can be added to a systemThe gateways provide I/O status and Error/Status messagingNon-safety related information can be sent to the Flexi Soft from the networkAddressing ...