Fluke I430-FLEXI-TF-II-4PK Power Quality Analyser Clamp, Accessory Type Flexible AC Current Probe

  • RS-artikelnummer 818-7350
  • Tillv. art.nr I430-FLEXI-TF-II-4PK
  • Tillverkare / varumärke Fluke
Datablad
Lagstiftning och ursprungsland
Ej tillämpbart
COO (Country of Origin): RO
Produktdetaljer

i430-Flexi-TF-II 6000A Flexible AC Current Probe

The i430-Flexi-TF-II flexible AC current probe is optimized for current measurement on thick and hard to reach conductors. The i430-Flexi-TF-II is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II.

Measuring range: 0.5 to 6000 A ac
Bandwidth (-3 dB): 10 Hz to 10 kHz
Output signal: 86.6 mV at 1000A/50Hz (on 1 MΩ), 85.0 mV at 1000A/50Hz (on 50 kΩ)
Maximum non-destructive current: 100 kA (50/60 Hz)
Transducer length: 610 mm (24 in)
Transducer diameter: 7.5 mm (0.3 in)
Minimum bending radius: 38 mm (1.5 in)
Cable length from transducer to BNC: 2.5 m (98.4 in)
Complies with: IEC 61010-1: Pollution degree 2, IEC 61010-2-032: 1000V CAT III/ 600V CAT IV, IEC 61010-031

Supplied with

Instruction Sheet

Fluke Flexible AC Current Probe

The Fluke flexible AC current probe has a current measuring range from 0.5A to 6000A. This lightweight measuring head allows quick and easy installation in hard to reach areas, without batteries or an external power source. It is also available as a pack of 4 pieces of the i430 current clamp, to be used for high current measurements. The Flex clamp fits around bus bars and large or hard-to-reach conductors. This 4 pack is perfect for use with 3-phase tools such as the Fluke 430 series.Supplied withInstruction Sheet

Features and Benefits

Bandwidth (-3dB): 10Hz to 10kHz Output signal is 86.6mV at 1000A/50Hz (on 1 Mohm), 85.0mV at 1000A/50Hz (on 50kohm) Maximum non-destructive current is 100kA (50/60Hz) The transducer length is 610mm (24in) The transducer diameter is 7.5mm (0.3in) Minimum bending radius is 38mm (1.5in) Cable length from transducer to BNC: 2.5m (98.4in)

Certifications

IEC 61010-1: Pollution degree 2 IEC 61010-2-032: 1000V CAT III/ 600V CAT IV safety rated IEC 61010-031 UL94 approved IP41 rated CE CSA certified

Specifikationer
Attribute Value
Accessory Type Flexible AC Current Probe
For Use With Fluke 433/434/435/434-II/435-II/437-II
2 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
Tidigare 12 904,32 kr
11 768,00 kr
(exkl. moms)
14 710,00 kr
(inkl. moms)
Enheter
Per unit
1 +
11 768,00 kr
Related Products
Dual range a.c. current clamp nominal measuring ranges ...
Description:
Dual range a.c. current clamp nominal measuring ranges 0.1A to 20A a.c. and 0.5A to 200A a.c.Safe, non intrusive current measurement40Hz to 10kHz bandwidthErgonomic jaw design for measurement where access is difficult and allows 'hooking' onto the cableMax. conductor size ...
The CA8220 is optimised for maintenance and troubleshooting ...
Description:
The CA8220 is optimised for maintenance and troubleshooting of electrical equipment, electrical systems and in single phase and balance three phase systems.,The CA8220 includes measurements for testing and monitoring rotating machines in operation. including temperature, current , duration of in-rush ...
Fluke power quality analysers help locate, predict, prevent ...
Description:
Fluke power quality analysers help locate, predict, prevent and troubleshoot problems in power distribution systems and include many features to capture details to pinpoint problems quickly and safely. Troubleshooting is fast with on-screen display of trends and captured events, even ...
Fluke power quality analysers help locate, predict, prevent ...
Description:
Fluke power quality analysers help locate, predict, prevent and troubleshoot problems in power distribution systems and include many features to capture details to pinpoint problems quickly and safely. Troubleshooting is fast with on-screen display of trends and captured events, even ...