Megger LTW425 Loop Impedance & RCD Combined Tester, Loop Impedance Test Type 2 Wire 440V, RCD Test Type AC Selective

  • RS-artikelnummer 237-883
  • Tillv. art.nr LTW425-RS-BS
  • Tillverkare / varumärke Megger
Datablad
Lagstiftning och ursprungsland
Ej tillämpbart
COO (Country of Origin): GB
Produktdetaljer

LTW425

The Megger LTW425 two wire earth loop tester verifies the loop impedance of a live electrical circuit, ie without the need to disconnect the electrical supply. Offers a high resolution 2-wire loop testing solution that does not trip 30 mA RCDs and can be used on a wide range of voltages.

High resolution (0.001Ω) 2 wire testing + maxZ + (R1+R2)
Backlit display
2 wire loop tests: Phase to Earth, Phase to Neutral or Phase to Phase
3 phase circuits with RCD protection can be tested
Tests radial circuits where the circuit does not return to the origin, even where only a phase and neutral contacts are available.
10 second non trip loop test time with Auto test extension up to a further 10 seconds if noise is detected, to improve the accuracy of the test
High current loop testing for supplies that do not have an RCD fitted
AUTO START will start the loop test running as soon as the test leads are connected; No need to press the test button means much safer testing
PFC Display up to 40kA
Voltage and frequency measurement
110 Vac systems including 110V centre tap to earth (55 V phase to earth) can be tested on the secondary winding.
IP54 Weatherproof case
Optional 10A fused 2 wired test leads and crocodile clip set
Complies with IEC61010-1 300V CATIV safety standard and meets EN61557

Note

RS is an authorised Megger distributor. Purchased though RS this product is eligible for the Megger extended 3 Year warranty

Supplied with

Test lead set with crocodile clips, mains socket test lead, 8 AA alkaline batteries, hard carry case and instructions.

Specifikationer
Attribute Value
Loop Impedance Test Type 2 Wire
Calibrated RSCAL
Maximum Voltage Measurement 440V
RCD Test Type AC Selective
Best Loop Test Accuracy ±10%
RCD Test Current 4A
Non-Trip Loop Test Yes
Safety Category CAT IV 300 V, IEC 61010
Display Type LCD
Battery Life 2000 Tests
Battery Type AA
Power Source Battery
Dimensions 203 x 148 x 78mm
Weight 1kg
Maximum Operating Temperature +50°C
Height 78mm
Minimum Operating Temperature -10°C
Safety Category Voltage 300V
Safety Category Level CAT IV
Model Number p LTW425
Length 203mm
Width 148mm
2 I lager för leverans inom 3-5 arbetsdagar
Pris (ex. moms) Each
8 523,99 kr
(exkl. moms)
10 654,99 kr
(inkl. moms)
Enheter
Per unit
1 +
8 523,99 kr
Nästa dag-leverans inte möjlig
Related Products
Offering data storage and download capabilities via a ...
Description:
Offering data storage and download capabilities via a USB port, the Fluke 1623-2 can perform 4 types of earth ground measurement. This tester is able to measure ground loop resistance using only clamps, this method doesn't require the use of ...
All instruments meet IEC1010, HD384 and BSEN61557, and ...
Description:
All instruments meet IEC1010, HD384 and BSEN61557, and are sealed to IP54 for weatherproof performance.Easy to hold and comfortable to use, the large display provides the unique combination of two digital readouts and an analogue arc.All primary results are displayed ...
All instruments meet IEC1010, HD384 and BSEN61557, and ...
Description:
All instruments meet IEC1010, HD384 and BSEN61557, and are sealed to IP54 for weatherproof performance.Easy to hold and comfortable to use, the large display provides the unique combination of two digital readouts and an analogue arc.All primary results are displayed ...
MIT480 mk2 Series insulation & continuity testers replace ...
Description:
MIT480 mk2 Series insulation & continuity testers replace the original MIT480 range. Designed for the Telecommunication and Cable testing markets. The tester features a redesigned case, back-stand and 6 cell battery compartment with separate fuse access. Insulation testing up to ...