TRACOPOWER THP 3 DC-DC Converter, 5V dc/ ±100mA Output, 36 → 160 V dc Input, 3W, Through Hole, +85°C Max Temp
- RS-artikelnummer:
- 166-5381
- Tillv. art.nr:
- THP 3-7211
- Tillverkare / varumärke:
- TRACOPOWER
Tillfälligt slut i lager – restorder för leverans 2024-08-09
Lagt till varukorgen
Pris (ex. moms) 1 rör med 10
5 826,43 kr
(exkl. moms)
7 283,04 kr
(inkl. moms)
Rör | Per Tube | Per unit* |
1 - 4 | 5 826,43 kr | 582,643 kr |
5 - 9 | 5 651,60 kr | 565,16 kr |
10 - 24 | 5 476,89 kr | 547,689 kr |
25 - 49 | 5 243,76 kr | 524,376 kr |
50 + | 5 010,74 kr | 501,074 kr |
- RS-artikelnummer:
- 166-5381
- Tillv. art.nr:
- THP 3-7211
- Tillverkare / varumärke:
- TRACOPOWER
Datablad
Lagstiftning och ursprungsland
- COO (Country of Origin):
- TW
Produktdetaljer
Traco 3W DIP Single/Dual Output Regulated Isolated DC-DC Converter - THP 3 Series
The Tracopower THP-3 series is a new range of high performance 3W DC/DC converters in a low profile DIL-24 package with standard industry pin-out. The very high I/O-isolation system of these DC-DC converters and input voltages up to 160 Vdc make the THP-3 the best choice for many demanding applications in railroad and transpor¬tation systems, medical equipment, instrumentation, everywhere where high basic, supplementary, or reinforced insulation is requested to meet specific safety stan¬dards. The high efficiency of the THP-3 allows safe operation in a temperature range of –40C to +75C at full load. The full SMD-design with exclusive use of ceramic capacitors of these DC-DC converters ensures a very high reliability and a long product lifetime.
Supplementary and reinforced insulation
I/O isolation 3000 VACrms rated for 300 Vrms working voltage
Medical safety to UL 60601-1 and IEC/EN 60601-1 3rd Edition, 2 x MOOP
Industrial safety to IEC/EN/UL 60950-1
9-40 VDC, 18-80 VDC and 36-160 VDC
Extended operating temperature range –40°C to 85°C max.
Input filter meets EN55022A without ext. components
Continuous short circuit protection
High reliability, MTBF >1 Mio. hours
Lead free design, RoHS compliant
3-year product warranty
I/O isolation 3000 VACrms rated for 300 Vrms working voltage
Medical safety to UL 60601-1 and IEC/EN 60601-1 3rd Edition, 2 x MOOP
Industrial safety to IEC/EN/UL 60950-1
9-40 VDC, 18-80 VDC and 36-160 VDC
Extended operating temperature range –40°C to 85°C max.
Input filter meets EN55022A without ext. components
Continuous short circuit protection
High reliability, MTBF >1 Mio. hours
Lead free design, RoHS compliant
3-year product warranty
Note
Derates 4% per °C above 75°C.
MTBF to MIL-HDBK-217F (25°C).
MTBF to MIL-HDBK-217F (25°C).
Standards
EN 60950-1, UL60950-1, IEC 60950-1, CSA C22.2 No. 60950-1-03, EN 60601-1, UL 60601-1, IEC 60601-1, EN 50124-1&2, CSA C22.2 No. 601-1
Approvals
CB, CSA
Specifikationer
Attribute | Value |
---|---|
Output Voltage | 5V dc |
Input Voltage Range | 36 → 160 V dc |
Power Rating | 3W |
Input Voltage Nominal | 72 V dc |
Output Current | ±100mA |
Mounting Type | Through Hole |
Isolated | Yes |
Number of Outputs | 1 |
Package | DIL 24 |
Isolation Voltage | 4kV dc |
Length | 32mm |
Depth | 10mm |
Railway Approved | No |
Series | THP 3 |
Load Regulation | ±1% |
Maximum Temperature | +85°C |
Medical Approved | Yes |
Minimum Temperature | -40°C |