XP Power JHL03 DC-DC Converter, 5V dc/ 600mA Output, 10 → 17 V dc Input, 3W, Through Hole, +80°C Max Temp -20°C
- RS-artikelnummer:
- 161-8873
- Tillv. art.nr:
- JHL0312S05
- Tillverkare / varumärke:
- XP Power
2 I lager för avsändande samma dag
Lagt till varukorgen
Pris (ex. moms) 1 rör med 10
3 205,53 kr
(exkl. moms)
4 006,91 kr
(inkl. moms)
Rör | Per Tube | Per unit* |
1 - 4 | 3 205,53 kr | 320,553 kr |
5 - 9 | 3 109,37 kr | 310,937 kr |
10 - 24 | 3 013,20 kr | 301,32 kr |
25 - 49 | 2 917,04 kr | 291,704 kr |
50 + | 2 820,88 kr | 282,088 kr |
- RS-artikelnummer:
- 161-8873
- Tillv. art.nr:
- JHL0312S05
- Tillverkare / varumärke:
- XP Power
Datablad
Lagstiftning och ursprungsland
- COO (Country of Origin):
- TW
Produktdetaljer
XP Power - JHL03 Series of Isolated DC-DC Converters
The JHL03 series offers a highly reliable range of single and dual output, 3 W, isolated DC-DC converters. The series features 4000 V ac reinforced insulation, 2 μA patient leakage current and is available in an industry standard DIP24 package. These compact DC-DC converters are internationally medical approved, meet IEC60601-1, 3rd Edition and EN55011 level A with no external components. The range has an efficiency of up to 87% and a wide -40 °C to +80 °C operating temperature range, making them the perfect choice for a host of commercial and industrial applications.
3 W, isolated DC-DC converters
Wide -40 °C to +80 °C operating temperature range
Internationally medical approved
Industry standard DIP24 package
4000 V ac reinforced insulation
2 μA patient leakage current
Meets IEC60601-1, 3rd Edition
Wide -40 °C to +80 °C operating temperature range
Internationally medical approved
Industry standard DIP24 package
4000 V ac reinforced insulation
2 μA patient leakage current
Meets IEC60601-1, 3rd Edition
XP Power Isolated DC-DC Converters
Specifikationer
Attribute | Value |
---|---|
Output Voltage | 5V dc |
Input Voltage Range | 10 → 17 V dc |
Power Rating | 3W |
Input Voltage Nominal | 12 V dc |
Output Current | 600mA |
Mounting Type | Through Hole |
Isolated | Yes |
Number of Outputs | 1 |
Package | DIP 24 |
Isolation Voltage | 4kV ac |
Length | 31.75mm |
Width | 20.32mm |
Depth | 10.2mm |
Railway Approved | No |
Series | JHL03 |
Load Regulation | ±1% |
Standards Met | ANSI/AAMI ES60601-1, CSA-22.2 No.60601-1:2008, EN55011, EN60068-2-27, EN60068-2-47, EN60068-2-6, EN60601-1, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC60601-1, IEC60601-1-2, MIL-HDBK-217F |
Minimum Temperature | -20°C |
Medical Approved | Yes |
Efficiency | 76% |
Maximum Temperature | +80°C |