TRACOPOWER TIM 2 DC-DC Converter, 12V dc/ 167mA Output, 18 → 36 V dc Input, 2W, Through Hole, +105°C Max Temp
- RS-artikelnummer:
- 152-6552
- Tillv. art.nr:
- TIM 2-2412
- Tillverkare / varumärke:
- TRACOPOWER
Tillfälligt slut i lager – restorder för leverans 2024-09-02
Pris (ex. moms) 1 rör med 10
2 870,87 kr
(exkl. moms)
3 588,59 kr
(inkl. moms)
Rör | Per Tube | Per unit* |
1 - 4 | 2 870,87 kr | 287,087 kr |
5 - 9 | 2 784,78 kr | 278,478 kr |
10 - 24 | 2 698,57 kr | 269,857 kr |
25 - 49 | 2 583,81 kr | 258,381 kr |
50 + | 2 468,94 kr | 246,894 kr |
- RS-artikelnummer:
- 152-6552
- Tillv. art.nr:
- TIM 2-2412
- Tillverkare / varumärke:
- TRACOPOWER
Lagstiftning och ursprungsland
- COO (Country of Origin):
- TW
Produktdetaljer
Medical/Reinforced I/O-Isolation DC/DC Converters 2 - 30 Watt
2 Watt DC/DC converter in DIP-16 package
Certification to IEC/ES 60601-1 3rd edition for 2 x MOPP
I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Risk management file acc. ISO 14971
Quality to ISO 13485, IPC-A-610 level 3
5-year product warranty
2:1 input voltage with extended low input range:4.5-12, 9-18, 18-36, 36-75
Output voltages:5.0, 12, 15, 24, ±12, ±15 VDC
I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Low leakage current
Input filter to meet EN55022 class A
I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Risk management file acc. ISO 14971
Quality to ISO 13485, IPC-A-610 level 3
5-year product warranty
2:1 input voltage with extended low input range:4.5-12, 9-18, 18-36, 36-75
Output voltages:5.0, 12, 15, 24, ±12, ±15 VDC
I/O isolation 5000 VACrms rated for 250 VACrms working voltage
Low leakage current
Input filter to meet EN55022 class A
Specifikationer
Attribute | Value |
---|---|
Output Voltage | 12V dc |
Input Voltage Range | 18 → 36 V dc |
Power Rating | 2W |
Input Voltage Nominal | 24 V dc |
Output Current | 167mA |
Mounting Type | Through Hole |
Isolated | Yes |
Number of Outputs | 1 |
Package | DIP 16 |
Isolation Voltage | 5kV ac |
Width | 14.4mm |
Depth | 10.2mm |
Length | 24.3mm |
Series | TIM 2 |
Load Regulation | 0.01 |
Maximum Temperature | +105°C |
Efficiency | 81% |
Medical Approved | Yes |
Minimum Temperature | -40°C |
Standards Met | AAMI/ANSI ES 60601-1, EN 55022, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, IEC/EN 60601-1, MIL-STD-810F |