Fluke 566 Infrared Thermometer, Max Temperature +650°C, ±1 %, Centigrade, Fahrenheit With RS Calibration

  • RS-artikelnummer 413-879
  • Tillv. art.nr FLUKE 566
  • Tillverkare / varumärke Fluke
Datablad
Lagstiftning och ursprungsland
Ej tillämpbart
COO (Country of Origin): CN
Produktdetaljer

Fluke 566 IR Contact and Non-Contact Thermometer

A multipurpose thermometer combining infrared and contact capability, the Fluke 566 is straight forward and menu driven. Complex temperature measurement is made easy, the contact, non-contact combination provide the optimal measurement solution. Featuring quick navigation, emissivity adjustment and data logging all at the touch of a soft key button. MIN, MAX, AVG and DIF functions allow users to quickly troubleshoot, whilst 2 colour flashing alarms alert when a measurement has exceeded its limit.

The dot matrix display features 2 settings, normal and extra bright which make this an ideal device for all darker environments.

Features and Benefits:

• 98 x 96 pixels
• Soft keys and graphical display
• Log and downloads up to 99 measurements
• -40 °C to 650 °C (-40 °F to 1200 °F) temperature range
• 30:1 distance to spot ratio

Compatible with all standard mini-connector K-type thermocouples (1 included)

FAQ's

Are infrared thermometers dangerous?

Infrared thermometers are not harmful, they do not emit radiation, only measure it like a digital camera.

How accurate are infrared thermometers?

The majority of IR thermometers have a measurement error specification, which shows their best accuracy. The surface being measured can also affect accuracy. Reflective objects result in lower measurements than the actual temperature, whilst non-reflective surfaces give higher measurement. The emissivity of a surface is how effective it is at emitting energy as thermal radiation, as such some IR thermometers have adjustable emissivity settings.
Distance to spot ratio is also essential in providing accurate temperature measurements, if an infrared thermometer is too close to its target area, heat can build up in the device. This can give false readings or damage the temperature sensors, therefore it is essential to always follow a manufacturers guidelines.

Supplied with

Hard carry case, type K bead thermocouple, 2 x AA batteries, quick start guide and user manual on CD-ROM

Buy Fluke products and claim another Fluke product free.
Between September 1, 2020 and December 15, 2020 customer who purchase a Fluke product (inc. Fluke Networks) have the opportunity to claim a free product through the Fluke website with the original proof of purchase, invoice, or receipt. The product can be claimed by visiting the Fluke website -
www.fluke.ie/freefluke (Ireland)
www.fluke.be/freefluke (Belgium)
www.fluke.nl/freefluke (Netherlands)
www/fluke.no/freefluke (Norway)
www.fluke.se/freefluke (Sweden)
www.fluke.com/en/freefluke (South Africa)
There are six levels of free tools to claim. They are separated based on the value of the qualifying purchase, starting at as little as only €100. For each level there is a fixed range of products to claim, based on the value of the original purchase.

Specifikationer
Attribute Value
Absolute Maximum Temperature Measurement +650°C
Temperature Scale Centigrade, Fahrenheit
Calibrated RSCAL
Distance to Spot Ratio 30:1
Best Accuracy ±1 %
Absolute Minimum Temperature Measurement -40°C
Emissivity 0.1 → 1
Model Number p 566
Resolution 0.1 °C
Data Storage Yes
Response Time 500 ms
Length 254mm
Width 191mm
Height 69mm
Dimensions 254 x 191 x 69mm
Weight 965g
13 I lager för leverans inom 3-5 arbetsdagar
Pris (ex. moms) Each
5 209,00 kr
(exkl. moms)
6 511,25 kr
(inkl. moms)
Enheter
Per unit
1 +
5 209,00 kr
Nästa dag-leverans inte möjlig
Related Products
Display (3-line) with backlightLens with 13 mm measuring ...
Description:
Display (3-line) with backlightLens with 13 mm measuring spot up to 140 mm rangeMIN/MAX and HOLD functions, adjustable offset valueAdjustable visual and audible alarmLaser sight for marking the centre of the measuring spotAdjustable emissivityUSB interfaceOptrisConnect report software for evaluating measured ...
The Flir non-contact forehead IR thermometer Ideal for ...
Description:
The Flir non-contact forehead IR thermometer Ideal for quickly detecting elevated body temperature. This device is non-contact design eliminates need for replacement probe covers and other supplies. Non-contact technique can reduces potential spread of diseases from using contact devices. Adjustable ...
Easy-to-use battery operated electronic ear thermometer.,Suitable for all ...
Description:
Easy-to-use battery operated electronic ear thermometer.,Suitable for all ages, especially babies, young children and the elderly. One second measuring timeBeeps when temperature reachedIlluminated display for easy readingDisplay can be shown in either °C or °FAutomatically stores last 5 readings to ...
Temperature variances can indicate common mechanical and electrical ...
Description:
Temperature variances can indicate common mechanical and electrical problems. These can be diagnosed faster, safer and easier with the AutoPro ™ non-contact infrared thermometer, specifically designed for the automotive professional. Features SmartSight™ - 2 lasers merge into a single laser ...