Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches

These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.

Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)

Note

The XY2 CB switch must not be used if the installation requires that the trip wire be angled but the XY2 CE switch can. In this case, the total sum of the angles through which the trip wire bends must not exceed 180°.

Standards

EN/ISO 13850:2006

Specifikationer
Attribute Value
Normal State Configuration 2NO/2NC
Maximum AC Voltage 300V
Range Preventa
Series XY2-CE
Maximum Current 10 A
I lager för leverans inom 2 arbetsdagar
Pris (ex. moms) Each
2 788,84 kr
(exkl. moms)
3 486,05 kr
(inkl. moms)
Enheter
Per unit
1 +
2 788,84 kr
Nästa dag-leverans inte möjlig
Related Products
1. Operation of pedal up to pressure point:the ...
Description:
1. Operation of pedal up to pressure point:the work contact is closed and the work process is initiated.2. In an emergency situation, operate beyond the pressure point resistor:The work contact is stopped and locked and the work process is stopped. ...
Even under extreme conditions, such as major temperature ...
Description:
Even under extreme conditions, such as major temperature fluctuations, the SRM rope pull switch continues to work reliably. Rope pull switch manufactured in accordance with DIN EN 60947-5-5 and DIN EN ISO 13850Protection class IP67Stable and durable metal housing (aluminium ...
The XY2-CH emergncy stop rope pull switch (also ...
Description:
The XY2-CH emergncy stop rope pull switch (also known as a grab wire switch) is ideal for applications such as conveyor systems, packaging, textiles, transfer machines, presses, woodworking equipment, paint lines and test laboratories. For machine tools, conveyers & handling ...
Maximum system length: 75 mSwitch function: 2 NC ...
Description:
Maximum system length: 75 mSwitch function: 2 NC + 2 NO (standard)Built-in reset buttonCable pull eyelet, low costVisualisation of correct cable tensionMeets EN418 and IEC947-5-5Protection class IP67.