XY2-CE Cable Switch, Right Side, 50m, 2NO/2NC

Datablad
Lagstiftning och ursprungsland
Ej tillämpbart
COO (Country of Origin): MA
Produktdetaljer

Telemecanique XY2CE & XY2CB Emergency Stop Rope Pull Switches

These emergency stop trip wire switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal emergency stop function is not available and will also trip in the event of the trip wire breaking.

Switches incorporate positive opening operation contacts, the tripping of the switch being made with positive action
The switch latches in the tripped position (N/C safety contact(s) open). The function of the N/O contact is purely for signalling
Incorporates a reset button, which re-closes the safety contact(s), restarting of the machine must only be achieved by manual operation of a control device within the machine start circuit, remote to the trip wire switch
Recommended distance between cable supports is 15m (for model XY2-CB30 a distance of 20m is recommended)
The XY2 CE1A296 comes with a pilot light (direct supply)

Note

The XY2 CB switch must not be used if the installation requires that the trip wire be angled but the XY2 CE switch can. In this case, the total sum of the angles through which the trip wire bends must not exceed 180°.

Standards

EN/ISO 13850:2006

Specifikationer
Attribute Value
Range Preventa
Series XY2-CE
Reset Button Yes
Normal State Configuration 2NO/2NC
Mounting Orientation Right Side
Maximum Rope Span 50m
Maximum Current 10 A
Maximum AC Voltage 300V
Number of Cable Entries 3
Size of Cable Entries 0.5 in NPT
E-Stop Button No
I lager för leverans inom 2 arbetsdagar
Pris (ex. moms) Each
3 043,68 kr
(exkl. moms)
3 804,60 kr
(inkl. moms)
Enheter
Per unit
1 +
3 043,68 kr
Nästa dag-leverans inte möjlig
Related Products
Telemecanique XY2CED emergency stop dual rope pull switches ...
Description:
Telemecanique XY2CED emergency stop dual rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. These dual rope pull switches feature double anchor points and can support up ...
Telemecanique XY2CE EX ATEX emergency stop rope pull ...
Description:
Telemecanique XY2CE EX ATEX emergency stop rope pull switches are designed to reduce the risk of injury to persons and damage either to machines or work in progress. They can be tripped by a single human action when a normal ...
Our Lifeline™ 4 Cable Pull Switches can be ...
Description:
Our Lifeline™ 4 Cable Pull Switches can be installed along or around awkward machinery such as conveyors and provide a constant emergency stop access. The system includes a rope status indicator and emergency stop button mounted on the switch lid. ...
The Telemecanique sensors XY2CE is 240VAC rated voltage ...
Description:
The Telemecanique sensors XY2CE is 240VAC rated voltage wire switch. It has E-stop rope pull switch on left side-2NC+2NO with yellow pilot light, 230V-boot. • Contact operation slow break• Cover material is stainless steel• Housing material is Zamak• Maximum rope ...