KANE458KIT Combustion Gas Analyser

  • RS-artikelnummer 181-0418
  • Tillv. art.nr KANE458KIT
  • Tillverkare / varumärke Kane
Datablad
Lagstiftning och ursprungsland
Und.t.
COO (Country of Origin): GB
Produktdetaljer

Kane Combustion Gas Analyser

The Kane combustion gas analyser comes with infrared technology to directly measure CO₂. It has a rotary switch that permits the user to select and view the readings of the test being performed, an in-built torch light, 30-second start-up, six line display with screen protection, a dual pump system for CO sensor protection. CO2 directs with an infrared sensor 0-20%. This analyser helps to measure CO 0-2, 000ppm, differential temperature, high accuracy differential pressure meter +/- 80mbar O2, excess air, CO/CO2 ratio and combustion efficiency of various fuels (natural gas, butane, propane, LPG, 28 sec oil, 35 sec oil, wood pellets, etc.)

Features and Benefits

• Structured commission test
• Rotary switch for ease of use
• Data hold
• Logs and prints reports for combustion, pressure, let-by & tightness, temperature, CO build up and commission test
• Optional infrared printer option available
• 5-year warranty, if serviced annually by Kane

Applications

• Installation and servicing of domestic oil or gas appliances
• Safety checks
• CO in a room or around an appliance
• Combustion performance checks
• Combustion efficiency checks
• Flue draught

Certifications

• BS EN 50379:2004

Specifikationer
Attribute Value
Best Carbon Monoxide Accuracy ±5%
Carbon Monoxide Resolution 1
Best Carbon Dioxide Accuracy ±0.3%
Carbon Dioxide Resolution 0.1%
Best Oxygen Level Accuracy ±0.3%
Oxygen Level Resolution 0.1%
Maximum Temperature +50 (Internal) °C, +600 (External) °C, +600 (Flue) °C
Best Temperature Measurement Accuracy ±0.3 (External) %, ±0.3 (Flue) %, ±0.3 (Internal) %
Temperature Measurement Resolution ±0.1 (External) °C, ±0.1 (Flue) °C, ±0.1 (Internal) °C
Leak Testing Yes
Battery Type 4AA
Maximum Oxygen Level 21%
Weight 800g
Maximum Carbon Monoxide Level >2000 (Purge Pump Operate) ppm, 20 ppm, 2000 (Nom) ppm
Maximum Operating Temperature +45°C
Length 200mm
Maximum Carbon Dioxide Level 20%
Power Source Battery
Model Number p KANE458
Minimum Carbon Monoxide Level 0ppm
Width 45mm
Height 90mm
Minimum Carbon Dioxide Level 0%
Minimum Operating Temperature 0°C
Battery Life >8 h
Dimensions 200 x 45 x 90mm
Minimum Oxygen Level 0%
3 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
8 230,20 kr
(exkl. moms)
10 287,75 kr
(inkl. moms)
Enheter
Per unit
1 +
8 230,20 kr
Related Products
2 channel type K thermocouple thermometer Accepts a ...
Description:
2 channel type K thermocouple thermometer Accepts a wide range of Testo and other type K thermocouple probes with miniature K type connectorsCompatible with the Testo Radio Probe System to provide an additional temperature measurement Displays differential temperature Print out ...
The Kane 450 has an easy to use ...
Description:
The Kane 450 has an easy to use rotary switch and includes all the features expected of a “top of the range” analyser. Any four parameters can be displayed simultaneously. The high accuracy and stability of its pressure readings allow ...
The Kane 255 is capable of measuring CO, ...
Description:
The Kane 255 is capable of measuring CO, CO2 and temperature. It is a combustion flue gas analyser. The analyser can calculate O2, CO/CO2 ratio and efficiency for any appliance burning natural gas, propane, butane, LPG, light oils or wood ...