RS Components
Vår webbplats använder cookies och liknande teknik för att ge bättre service vid sökning och vid beställning, för analytiska ändamål och för att kunna anpassa vår marknadsföring till dig.
 
Sök efter P/N

Megger DET14C Earth & Ground Resistance Tester 1.5kΩ CAT IV 600 V


6 I lager för leverans inom 1 arbetsdagar
Add to Basket

Pris (ex. moms) Each

14 853,41 kr

(exkl. moms)

18 566,76 kr

(inkl. moms)

Enheter

Lagt till varukorgen

RS-artikelnummer:
705-9422
Tillv. art.nr:
1000-761
Tillverkare / varumärke:
Megger

Und.t.

COO (Country of Origin):
GB
EnheterPer unit
1 +14 853,41 kr

Megger Earth & Ground Resistance Tester


The Megger earth and ground resistance tester measure a 1.5kΩ absolute maximum resistance and having the CAT IV 600V safety category. It is calibrated by UKAS. This 4-pole earth tester is used to measure soil resistivity and resistance of earth rods and associated installations. It is supplied in a hard carry case together with auxiliary stakes and cables. An ICLAMP selective clamp is available separately and when used with the DET4TC allows the testing of an earth rod without the need to disconnect from the system. A VCLAMP is also available separately, which when used in conjunction with ICLAMP allows stakeless measurements to be made in situations where driving auxiliary stakes is not practical. It has a rechargeable battery-powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability.


Features and Benefits


256 test results storage and recall
37mm dia conductor and 50mm earth strap capacity
4 digit plus 6 digit backlit LCD display
Accuracy guaranteed for 50Hz and 60Hz.
Auto ranging and hold function
Extended battery life
Ground resistance range between 0.050Ω and 1500Ω
High and low resistance alarms
Low maintenance flat jaw interface
Maximum current is 100Arms continuous and 200Arms for 60s max at 50Hz and 60Hz
Measurement over the ranges between 16Hz and 400Hz.
Oval clamp for easy access to earth cables and earth straps
Real time date and timestamping of results
True RMS ground leakage current ranges between 0.2 mA and 35A
True RMS readings up to a crest factor of 5.0 (peak current 40A)


Applications


Buildings, pylons and RF transmitter sites
Lightening protection systems


Certifications


EN 61010-2-032
IEC 61557-13 Class 1
IEC 61557-5


AttributeValue
Absolute Maximum Resistance Measurement1.5kΩ
Best Accuracy1.5 %
Display TypeLCD
Safety CategoryCAT IV 600 V
Battery Life24 h
Battery TypeAA
Power SourceBattery
Dimensions248 x 114 x 49mm
Weight985g
Height49mm
IncludesBattery, Calibration Check, Carrying Strap, Case, User Manual
Length248mm
Maximum Operating Temperature+50°C
Measurement TypeEarth Resistance, Leakage Current
Width114mm
Model Number pDET14C
Minimum Operating Temperature-20°C