Legrand 100VA DIN Rail Transformer, 230V ac, 400V ac Primary, 24V ac Secondary

  • RS-artikelnummer 535-7733
  • Tillv. art.nr 0 442 33
  • Tillverkare / varumärke Legrand
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): FR
Produktdetaljer

Control Transformers

Safety isolating transformer single phase
DIN rail mount (up to 250VA) or Surface mount with screws (400VA & above)
Terminals with finger protection IP2x or xxB up to 400VA
New design provides interference filter between windings
Clear laser engraved markings
Suitable for maximum 50°C ambient, without de-rating

Standards

IEC 61-558-2-2 and 2-4 or 2-6

Supplied with

0V/earth connection link

Approvals

UL506, CSA

Specifikationer
Attribute Value
Primary Voltage Rating 230V ac, 400V ac
Secondary Voltage Rating 24V ac
Power Rating 100VA
Mounting Type DIN Rail
Length 113mm
Width 94mm
Depth 94mm
Dimensions 113 x 94 x 94mm
Maximum Temperature +50°C
Weight 2kg
45 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
759,37 kr
(exkl. moms)
949,21 kr
(inkl. moms)
Enheter
Per unit
1 - 9
759,37 kr
10 - 24
683,58 kr
25 - 49
673,86 kr
50 - 99
644,08 kr
100 +
611,82 kr
Related Products
A range of compact moulded case current transformers ...
Description:
A range of compact moulded case current transformers suitable for primary currents from 30A to 800A with built-in sealable terminal covers. For transforming various primary currents into,5A standard secondary using 20/30/40mm busbars or cables, or 28mm cables. Built-in sealable terminal ...
From Myyra, the 44000 Series of type EI ...
Description:
From Myyra, the 44000 Series of type EI transformers are professional safety transformers featuring an insulation of above 4000V. Inherently short circuit proof and comprising of non-flammable and self-extinguishing materials, the 44000 series of transformers are extrememly reliable. • Professional ...
230Va.c. 50 to 60Hz primarySingle or twin secondary ...
Description:
230Va.c. 50 to 60Hz primarySingle or twin secondary windings for series or parallel connection (For conformance reasons,0.35 to 3.2VA transformers with 2 x 15 and 2 x 18V outputs and all transformers with 2x 24V outputs should not have their ...
Single and twin secondary windings for series or ...
Description:
Single and twin secondary windings for series or parallel connectionVacuum resin moulded to UL94-V0 ratingLow inter-winding capacitanceLow radiated noise100% electrical and flash testedExtra fixing points for secure board mounting (25 VA and 36 VA).