Siemens 0.63kVA Isolating Transformer, 230V ac Primary 1 x, 24V ac Secondary

  • RS-artikelnummer 480-4941
  • Tillv. art.nr 4AM5242-4TN00-0EA0
  • Tillverkare / varumärke Siemens
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): DE
Produktdetaljer

Control transformers, 1-phase, 4AM Series

Use as power, safety or displacement transformers in accordance with the applicable EN norm
High short-term performance
Low switch-on power (switch-on rush)
Protect against short circuits and overloading with motor protection switches on main side
Electrically isolated coils
Screw terminal connectors

Standards

EN 61 558-2-1, EN 61 558-2-2, EN 61 558-2-4 (at U SEC > 50 V AC), EN 61 558-2-6,
VDE 0570

Approvals

CE, UL

Specifikationer
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 24V ac
Power Rating 0.63kVA
Mounting Type DIN Rail
Number of Outputs 1
Length 144mm
Width 152mm
Depth 110mm
Dimensions 144 x 152 x 110mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +40°C
Weight 7.9kg
I lager för leverans inom 2 arbetsdagar
Pris (ex. moms) Each
2 417,70 kr
(exkl. moms)
3 022,12 kr
(inkl. moms)
Enheter
Per unit
1 - 4
2 417,70 kr
5 - 9
2 318,43 kr
10 - 24
2 256,50 kr
25 - 49
2 169,75 kr
50 +
2 128,80 kr
Nästa dag-leverans inte möjlig
Related Products
Compact, open type control panel transformerFully shrouded screw ...
Description:
Compact, open type control panel transformerFully shrouded screw terminals with permanent markingDetailed product specification permanently marked on front of unitVA ratings compatible with available protection devicesDual standard primary winding 230 / 400Vac.
Compact, open type control panel transformerFully shrouded screw ...
Description:
Compact, open type control panel transformerFully shrouded screw terminals with permanent markingDetailed product specification permanently marked on front of unitVA ratings compatible with available protection devicesDual standard primary winding 230 / 400Vac.
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
Short-circuit proof safety isolating transformersResin encapsulated transformersStable plastic ...
Description:
Short-circuit proof safety isolating transformersResin encapsulated transformersStable plastic enclosureIntegrated fuse protection and thermal cut-out against overloading and short circuitsScrew-type terminals for the connecting leads on input and output sideMeet the requirements of IEC61 558, EN61 558, ...