Block 25VA Isolating Transformer, 230V ac Primary 1 x, 24V ac Secondary

  • RS-artikelnummer 399-1599
  • Tillv. art.nr ACT25
  • Tillverkare / varumärke Block
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): DE
Produktdetaljer

Isolating Transformers Short Circuit Proof

Short-circuit proof safety isolating transformers
Resin encapsulated transformers
Stable plastic enclosure
Integrated fuse protection and thermal cut-out against overloading and short circuits
Screw-type terminals for the connecting leads on input and output side
Meet the requirements of IEC61 558, EN61 558, VDE0570
Insulation Class B
Construction Class 2
Isolation: 3750 V (Primary to Secondary)

Approvals

8888

Standards

IEC61 558; EN61 558; VDE0570

Specifikationer
Attribute Value
Primary Voltage Rating 230V ac
Secondary Voltage Rating 24V ac
Power Rating 25VA
Number of Outputs 1
Length 106mm
Width 94mm
Depth 63mm
Dimensions 106 x 94 x 63mm
Minimum Operating Frequency 50Hz
Maximum Operating Frequency 60Hz
Maximum Temperature +40°C
Weight 950g
48 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
599,82 kr
(exkl. moms)
749,78 kr
(inkl. moms)
Enheter
Per unit
1 - 9
599,82 kr
10 - 24
563,74 kr
25 - 49
507,38 kr
50 - 99
456,61 kr
100 +
410,91 kr
Related Products
Description:
This range of covered (up to 320 VA) or uncovered (from 400 to 2500 VA) transformers features double winding.Secondary winding coupling series or parallel with signalling LED and earthing by internal jumpers (up to 320 VA) or plug-in jumpers (from ...
High quality safety and isolating transformers designed for ...
Description:
High quality safety and isolating transformers designed for use in control circuits and general applications Low loss noise laminations Dual standard primary winding 230 / 400Vac with +15V tap for input flexibility Dual secondaries are centre tapped. Earth terminal provided ...
Use as power, safety or displacement transformers in ...
Description:
Use as power, safety or displacement transformers in accordance with the applicable EN normHigh short-term performanceLow switch-on power (switch-on rush)Protect against short circuits and overloading with motor protection switches on main sideElectrically isolated coilsScrew terminal connectors.
Low inrush current control, safety isolating and isolating ...
Description:
Low inrush current control, safety isolating and isolating transformerScrew type terminals, fitted with screw mounting bracketsCompact design with ±20V tappings on the primary windingFor use up to +40°C ambient maximum.