HOBUT DIN Rail Mounted Circuit Transformer, -30 → +85 °C, 100:5

  • RS-artikelnummer 331-339
  • Tillv. art.nr CT132M100/5-2.5/1
  • Tillverkare / varumärke HOBUT
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): GB
Produktdetaljer

Compact Busbar/ Base Mounting Current Transformers - Series 13

A range of compact moulded case current transformers suitable for primary currents from 40A to 300A with built in sealable terminal covers. For transforming various primary currents into 5A standard secondary using up to 20mm diameter cables.

DIN rail mounting clip supplied
Built in sealable terminal covers
Mounting feet supplied
Narrow width: 45mm
Dimensions: H65 x W45 x D30mm
21mm aperture
Conforms to IEC185, BS 7626, BSEN 60044-1and IEC 60044-1
Rated system voltage: 0.72/3kV
Ambient temperature range: -30 to 85°C
Continuous current: 1.2 x rated current


CT Class Information for Series 16
331-395 - Class 1
331-547 - Class 1
331-373 - Class 0.5
331-367 - Class 0.5
331-446 - Class 0.5

Current Transformers

Specifikationer
Attribute Value
Current Ratio 100:5
Inner Diameter 21mm
Transformer Type DIN Rail Mounted
Overall Height 65mm
Overall Width 45mm
Overall Depth 30mm
Minimum Temperature -30°C
Maximum Temperature +85°C
74 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
154,38 kr
(exkl. moms)
192,98 kr
(inkl. moms)
Enheter
Per unit
1 - 4
154,38 kr
5 - 9
149,78 kr
10 +
143,63 kr
Related Products
Power consumption 2.5VA, 50/60HzAccuracy class120, 30 or 40mm ...
Description:
Power consumption 2.5VA, 50/60HzAccuracy class120, 30 or 40mm busbar mountingSuitable for circular conductors 35mm apertureMaximum aperture for bar conductors 40x10mm (type 7)Operating temperature range –30 to +85°CSecondary terminals M5 studs with lock washers, nuts and terminal coverFull scale deflection ...
A range of compact moulded case current transformers ...
Description:
A range of compact moulded case current transformers suitable for primary currents from 25A to 500A with built-in sealable terminal covers. For transforming various primary currents into 5A standard secondary current using 20mm or 30mm busbars or 24mm cables. DIN ...
Split current transformers with unique clip-together feature enabling ...
Description:
Split current transformers with unique clip-together feature enabling high speed permanent installationCan be installed into existing networks without disconnecting cables or busbarsAmbient temperature range: -30°C to 80°CFrequency range: 50-60HzInsulation voltagel: 3kV for 1 minuteContinuous current: 1.2 x rated ...
Set consisting of a 1 A measuring transducer ...
Description:
Set consisting of a 1 A measuring transducer and a Rogowski coil with signal line. Length of Rogowski coil: 300 mm, diameter: 95 mm. Length of signal line: 10 m. The Rogowski coil measures the AC current of busbars and ...