Honeywell CSN Series Closed Loop Current Sensor, 0 → 90A, 50mA output current

  • RS-artikelnummer 181-2141
  • Tillv. art.nr CSNP661
  • Tillverkare / varumärke Honeywell
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): CN
Produktdetaljer

High current & Multi-range (AC & DC)

Flexible alternative to the current shunt or transformers for the isolated measurement of a.c. or d.c. currents. Both types have plastic Bayblend KU1468 UL94-VO cases.,High current types have current sensors based on the hall effect and null balance method. The output is the balancing current which is a perfect image of the primary current reduced by the number of secondary turns at any time. It can be expressed as a voltage by passing it through a resistor.,Multi-range types are similar devices but with a wider measuring range. Up to 36A is possible using 5 primary turns and up to 43A using 7 primary turns.

//media.rs-online.com/t_line/LF305573-10.gif
//media.rs-online.com/t_line/LI181214-01.gif
Specifikationer
Attribute Value
Sensor Technology Closed Loop
Output Current Range 50mA
Nominal Current 0 → 90A
Supply Voltage 12 → 15 V dc
Sensor Type Hall Effect
Mounting Type PCB Mount
Frequency Bandwidth DC to 150 kHz
Accuracy ±0.5 %
Series CSN
Minimum Operating Temperature -40°C
Maximum Operating Temperature +85°C
Depth 14.45mm
Height 29.6mm
Width 36.6mm
27 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
324,23 kr
(exkl. moms)
405,29 kr
(inkl. moms)
Enheter
Per unit
1 - 4
324,23 kr
5 - 14
311,06 kr
15 +
300,88 kr
Related Products
Measures d.c. and a.c. pulsed and complex currents ...
Description:
Measures d.c. and a.c. pulsed and complex currents with galvanic isolation.,The transducer is capable of measuring nominal currents of 5, 6, 8, 12 and 25A by the use of a set of primary connection pins with an output of 24mA ...
For the electronic measurement of currents, DC, AC, ...
Description:
For the electronic measurement of currents, DC, AC, pulsed, providing galvanic separation between the primary circuit and the secondary circuit. A Hall effect device, which provides galvanic isolation between primary and secondary circuitsSelf extinguishing plastic caseIdeal for measuring voltages associated ...
Current transducers LF-S Series for the electronic measurement ...
Description:
Current transducers LF-S Series for the electronic measurement of currents: dc, ac, pulsed..., with galvanic separation between the primary circuit and the secondary circuit. They are speciallly designed for industrial applications. Measurement of ac, dc and pulsed currentsHigh Accuracy - ...
Measurement of continuous, alternating, pulsed and mixed currentsGalvanically ...
Description:
Measurement of continuous, alternating, pulsed and mixed currentsGalvanically isolated between inputs and measuring circuitSelf extinguishing plastic housing UL 94–V0Operating temperature range -10 to +85°C.