LEM HOP Series Open Loop Current Sensor, ±900A

  • RS-artikelnummer 497-334
  • Tillv. art.nr HOP 600-SB
  • Tillverkare / varumärke LEM
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): CN
Produktdetaljer

HOP series current sensors

Current sensors with rectangular split core..
Measurement of direct, alternating and pulse current with galvanic insulation.
Connection using Molex 5045-04/AG connector.
Compact size.
Hole diameter: 21 mm.

Specifikationer
Attribute Value
Sensor Technology Open Loop
Nominal Current ±900A
Supply Voltage 12 15 V
Sensor Type Hall Effect
Mounting Type Busbar, Panel Mount
Frequency Bandwidth DC to 8 kHz
Bore Size 41 x 12.5mm
Accuracy ±2 %
Series HOP
Minimum Operating Temperature -10°C
Maximum Operating Temperature +70°C
Depth 32.4mm
Height 49.8mm
Width 72mm
15 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
1 267,27 kr
(exkl. moms)
1 584,09 kr
(inkl. moms)
Enheter
Per unit
1 - 4
1 267,27 kr
5 - 11
1 228,46 kr
12 +
1 188,80 kr
Related Products
These modules are designed to electronically measure continuous, ...
Description:
These modules are designed to electronically measure continuous, alternating, pulse and mixed currents.Provides galvanic insulation between the power device and the measurement.Excellent dynamic performance.Compact.Solder connection on printed circuit boards (recommended drilling Ø: 0.9 mm).
Open loop current transducer with Hall effect measuring ...
Description:
Open loop current transducer with Hall effect measuring principleFor measuring DC, AC and pulse currentsWith galvanic separation between primary and secondary circuitsUnipolar voltage supplyFixed offset voltage with corresponding amplificationHousing made from insulating, self-extinguishing material UL94-V0.
Sifam Tinsley Theta 20A/20V compact programmable transducers measure ...
Description:
Sifam Tinsley Theta 20A/20V compact programmable transducers measure and convert AC voltage or current input into a load independent DC output signal. Featuring an LCD display and are on-site configurable. True RMS measurement On-site programmable inputs On-site selectable output: DC ...
Sifam Tinsley Theta Hz programmable transducer is used ...
Description:
Sifam Tinsley Theta Hz programmable transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or DC Voltage. On-site programmable inputs On-site selectable output: DC Current or DC Voltage ...