ABB Thermal Overload Relay NO+NC, 33 A, 6 A, 690 V ac

  • RS-artikelnummer 800-7368
  • Tillv. art.nr 1SAZ811201R1002
  • Tillverkare / varumärke ABB
Datablad
Lagstiftning och ursprungsland
Und.t.
COO (Country of Origin): CN
Produktdetaljer

TF65 and TF96 Thermal Overload Relays

Thermal overload relays are protection devices used mainly to protect motors against overload and phase failures.

Overload protection – trip class 10
Rated temperature from -25 … +60 °C
Adjustable current setting for overload protection
Automatic or manual reset selectable
Suitable for three and single-phase application
Status indication
STOP and TEST function

Specifikationer
Attribute Value
FLC Motor Rating 33 A
Control Voltage 690 V ac
Contact Current Rating 6 A
Pole Configuration 3P
Range AF Range
Contact Voltage Rating 600 V ac/dc
Mounting Style Under Contactor Mount
Supply Voltage 690 V ac
Series TF65
Normal State Configuration NO+NC
Number Of Auxiliary Contacts 2
Terminal Type Flat
Reset Method Automatic, Manual
Width 87.7mm
Length 64.9mm
Depth 106.9mm
Minimum Operating Temperature -25°C
Operating Temperature Range -25 → +60 °C
Maximum Operating Temperature +60°C
1 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
1 098,11 kr
(exkl. moms)
1 372,64 kr
(inkl. moms)
Enheter
Per unit
1 - 9
1 098,11 kr
10 - 14
1 053,63 kr
15 +
1 007,93 kr
Related Products
Protects motor against overload and phase lossTrip class ...
Description:
Protects motor against overload and phase lossTrip class 10Auxiliary switch 1N/O and 1N/CStable, shock-resistant direct mounting on 100-K contactorBuilt in trip contact 95//96 and signal contact 97//98Auto/manual reset selectable on devicevisible trip indicationTest/trip actuatorStop actuator.
Type RF38, phase failure sensitive, manual or automatic ...
Description:
Type RF38, phase failure sensitive, manual or automatic resettingType RFN38, non phase failure sensitive, manual or automatic resettingType RF82 and RF95, phase failure sensitive, manual resettingType RFA82 and RFA95, phase failure sensitive, automatic resettingType RFN82 and RFN95, non phase failure ...
Phase failure sensitiveTest ButtonTrip-Fault IndicationManual or automatic reset ...
Description:
Phase failure sensitiveTest ButtonTrip-Fault IndicationManual or automatic reset facilityTemp. compensated trip -20 to +55°C.
One N/O and one N/C auxiliary contactTrip class ...
Description:
One N/O and one N/C auxiliary contactTrip class 10AManual/auto reset80 x 44 x 94mm (H x W x D) (4 to 11kW) Vertical mountingFor use with A series contactors4 to 11 kW for contactor series A9 to A30.