Schneider Electric Thermal Overload Relay NO/NC, 12 → 18 A, 18 A

Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): FR
Produktdetaljer

Three-pole Thermal Overload Relays

Three-pole thermal overload relays designed to protect ac circuits against overloads, phase failure, long starting times and prolonged stalling of the motor.

Adjustable relay setting dial
Test button
Stop button
Manual/auto reset
Trip indicator
Sealable cover
1N/O & 1N/C auxiliary contacts
Direct mounting beneath three-pole contactors or independent mounting on DIN rail
Insulation voltage 600V, Withstand Voltage 6kV

Approvals

UL and CSA

Specifikationer
Attribute Value
FLC Motor Rating 12 → 18 A
Contact Current Rating 18 A
Range TeSys D
Contact Voltage Rating 1 kV ac
Mounting Style DIN Rail Mount, Plate
Series LRD3
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Terminal Type Screw
Depth 116mm
Width 55mm
Length 70mm
Minimum Operating Temperature -20°C
Maximum Operating Temperature +60°C
Operating Temperature Range -20 → +60 °C
2 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
692,86 kr
(exkl. moms)
866,08 kr
(inkl. moms)
Enheter
Per unit
1 - 9
692,86 kr
10 - 14
664,73 kr
15 +
635,92 kr
Related Products
Designed to create extremely compact motor starters, the ...
Description:
Designed to create extremely compact motor starters, the LR9 series can be mounted below the LC1-D115/150 and LC1-E contactors (1, 3 or 4 pole F range contactors), Featuring built in alarm function this range of overload relays have a high ...
Manual or automatic re-settings availableDirect mounting on BF09 ...
Description:
Manual or automatic re-settings availableDirect mounting on BF09 - BF38 contactorsRated insulation voltage Ui: 690VFrequency limit 0-400HzOperating temperature -25 to +60°CCan be mounted on contactor or seperatelyTest button - trip indicator.
Electronic overload relays are the alternative to the ...
Description:
Electronic overload relays are the alternative to the thermal overload relays; they offer reliable and fast protection for motors in the event of overload or phase failure. Overload protection – trip class 10E, 20E, 30E selectablePhase loss sensitivityAdjustable current setting ...
TF range up to 38 AmpsOverload protection class ...
Description:
TF range up to 38 AmpsOverload protection class 10 but does have a adjustable setting Phase loss sensitivityAutomatic or manual reset selectableSTOP and Test function Temperature consumption -25 → +60 °C.