Siemens Overload Relay NO/NC, 20 → 25 A, 25 A, 11 kW

  • RS-artikelnummer 706-1673
  • Tillv. art.nr 3RU2126-4DB0
  • Tillverkare / varumärke Siemens
Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
COO (Country of Origin): DE
Produktdetaljer

Overload Relay - 3RU range

Switch position indicator and test function
STOP button
Selector switch for manual/automatic reset
Screw connection or Spring-clamp versions
Impulse voltage resistance 6 kV
Insulation voltage 690V
Surface or DIN-rail stand-alone mounts available, see 706-1699 etc

The 3RU21 thermal overload relays up to 80 A have been designed for current-sensitive protection of loads with normal starting.
These thermal overload relays for use with Sirius Size S0 & S00 Contactors

Note

Screw terminals can only be used with screw terminal overloads and spring terminals can only be used with spring terminal overloads.

Approvals

CE, UL, CSA

Siemens Sirius Range Contactor & Control Relays

Specifikationer
Attribute Value
FLC Motor Rating 20 → 25 A
Contact Current Rating 25 A
Pole Configuration 3P
Range Sirius Innovation
Contact Voltage Rating 690 V ac
Mounting Style Direct Contactor
Series 3RU
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Power Rating 11 kW
Reset Method Automatic, Manual
Terminal Type Screw
Width 45mm
Depth 73mm
Length 87mm
Maximum Operating Temperature +70°C
Operating Temperature Range -40 → +70 °C
Minimum Operating Temperature -40°C
5 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
647,28 kr
(exkl. moms)
809,10 kr
(inkl. moms)
Enheter
Per unit
1 - 9
647,28 kr
10 - 14
608,45 kr
15 +
582,56 kr
Related Products
Tripping class 10 Phase failure sensitivityHand, Automatic or ...
Description:
Tripping class 10 Phase failure sensitivityHand, Automatic or manual reset selectable.
Type RF38, phase failure sensitive, manual or automatic ...
Description:
Type RF38, phase failure sensitive, manual or automatic resettingType RFN38, non phase failure sensitive, manual or automatic resettingType RF82 and RF95, phase failure sensitive, manual resettingType RFA82 and RFA95, phase failure sensitive, automatic resettingType RFN82 and RFN95, non phase failure ...
Can be used with all motors equipped with ...
Description:
Can be used with all motors equipped with PTC thermistor probes. It monitors windings temperature and ensures that the rated operating value is not exceeded, therefore guarding against faults which are often the cause of premature ageing. They can also ...
Schneider Electrics K thermal overload relays are adjustable ...
Description:
Schneider Electrics K thermal overload relays are adjustable from 0.11 to 11.5 A, they have been predominantly designed for use in applications that require motor protection.This range of mini thermal overload relays feature compensated and phase failure sensitivity, the range ...