ABB Thermal Overload Relay NO/NC, 6 → 8.5 A, 8.5 A, 2.2 W

  • RS-artikelnummer 445-7927
  • Tillv. art.nr 1SAZ211201R1040
  • Tillverkare / varumärke ABB
Datablad
Lagstiftning och ursprungsland
Ej tillämpbart
Produktdetaljer

Thermal Overload Relays Type TA 25

One N/O and one N/C auxiliary contact
Trip class 10A
Manual/auto reset
80 x 44 x 94mm (H x W x D) (4 to 11kW)
Vertical mounting
For use with A series contactors
4 to 11 kW for contactor series A9 to A30

Note

ONLY SUITABLE FOR USE WITH 'A' SERIES CONTACTORS

Specifikationer
Attribute Value
FLC Motor Rating 6 → 8.5 A
Contact Current Rating 8.5 A
Pole Configuration 3P
Range A Line
Contact Voltage Rating 690 V ac
Mounting Style Clip On
Series TA25
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Power Rating 2.2 W
Reset Method Automatic, Manual
Terminal Type Screw
Width 44mm
Length 80mm
Depth 94mm
Minimum Operating Temperature -25°C
Maximum Operating Temperature +55°C
Operating Temperature Range -25 → +55 °C
10 I lager för leverans inom 1 arbetsdagar
Inom 2 arbetsdag(ar) (UK lager)
Pris (ex. moms) Each
670,03 kr
(exkl. moms)
837,54 kr
(inkl. moms)
Enheter
Per unit
1 - 4
670,03 kr
5 - 9
643,04 kr
10 +
630,11 kr
Related Products
Protects motor against overload and phase lossTrip class ...
Description:
Protects motor against overload and phase lossTrip class 10Auxiliary switch 1N/O and 1N/CStable, shock-resistant direct mounting on 100-K contactorBuilt in trip contact 95//96 and signal contact 97//98Auto/manual reset selectable on devicevisible trip indicationTest/trip actuatorStop actuator.
Provide protection to motors or other machines which ...
Description:
Provide protection to motors or other machines which require the temperature of their windings to be monitored and not exceeded, otherwise serious damage may occur. a.c. or d.c. operating voltagesRated current; 6ADIN rail mountingCan be screw mounted using adaptor (stock ...
Relays may be used with an ac or ...
Description:
Relays may be used with an ac or dc supply. 1 x NO and 1 x NC contact. Trip fault indication. Manual or auto reset button. For more data, see Telemecanique TeSys D Range Contactors/Accessories. Trip Class 10A.
The solid-state design of the 193-E1 Plus overload ...
Description:
The solid-state design of the 193-E1 Plus overload relay provides accurate, reliable and repeatable protection. A wide 5:1 adjustment range, dip switch (on EE versions) and isolated contacts provide application flexibility. The line-side over moulded power connections provides a sturdy ...