Schneider Electric Thermal Overload Relay NO/NC, 10 → 14 A, 14 A, 100 W, 250 V dc, 690 V ac

Datablad
Lagstiftning och ursprungsland
RoHS-Försäkran
Produktdetaljer

Thermal Overload Relays

Phase failure sensitive
Test Button
Trip-Fault Indication
Manual or automatic reset facility
Temp. compensated trip -20 to +55°C

Standards

IEC 947, BS4941, VDE 0660, NFC63-650

Approvals

CSA, UL, DEMKO, NEMKO, SEMKO, FIMKO, PTB

Specifikationer
Attribute Value
FLC Motor Rating 10 → 14 A
Control Voltage 250 V dc, 690 V ac
Contact Current Rating 14 A
Pole Configuration 3P
Range TeSys
Contact Voltage Rating 690 V ac
Mounting Style Direct Contactor
Series LR2K
Normal State Configuration NO/NC
Number Of Auxiliary Contacts 2
Power Rating 100 W
Terminal Type Screw
Reset Method Automatic, Manual
Length 116mm
Depth 65mm
Width 45mm
Minimum Operating Temperature -20°C
Operating Temperature Range -20 → +55 °C
Maximum Operating Temperature +55°C
10 I lager för leverans inom 1 arbetsdagar
Pris (ex. moms) Each
360,82 kr
(exkl. moms)
451,02 kr
(inkl. moms)
Enheter
Per unit
1 - 9
360,82 kr
10 - 14
346,18 kr
15 +
331,18 kr
Related Products
Protects motor against overload and phase lossTrip class ...
Description:
Protects motor against overload and phase lossTrip class 10Auxiliary switch 1N/O and 1N/CStable, shock-resistant direct mounting on 100-K contactorBuilt in trip contact 95//96 and signal contact 97//98Auto/manual reset selectable on devicevisible trip indicationTest/trip actuatorStop actuator.
The solid-state design of the 193-E1 Plus overload ...
Description:
The solid-state design of the 193-E1 Plus overload relay provides accurate, reliable and repeatable protection. A wide 5:1 adjustment range, dip switch (on EE versions) and isolated contacts provide application flexibility. The line-side over moulded power connections provides a sturdy ...
Suitable for machine protection requirements where machinery may ...
Description:
Suitable for machine protection requirements where machinery may be subject to difficult starting, jamming, high resistive torque/high inertia and/or mechanical failure1 N/O and 1 N/C contactLED status indication: Voltage, Starting, Steady State, Overload, TripTrip status monitored: Over-Current, Rotor Locked, ...
3RB30 and 3RB31 solid-state overload relays up to ...
Description:
3RB30 and 3RB31 solid-state overload relays up to 80 A with internal power supply have been designed for current-sensitive protection of loads with normal and heavy starting against excessive temperature rises due to overload, phase unbalance or phase failure. Switch ...