Lagstiftning och ursprungsland
RoHS-status: Inte relevant
Produktdetaljer
Eaton Bussmann HRC Offset Tag Fuses - BS88 British Standard Fuses
Eaton Bussmann's offset tag fuses (or offset bolted tag fuses) are essentially a cylindrical fuse that is fitted with offset brackets, these brackets allow the fuse to be bolted onto a fuse holder. Predominantly, this type of fuse is used within installations as a "weak link". They are designed to break when a fault occurs, such as an overcurrent or short circuit - they are a safety and damage measure. Eaton Bussmann's fuses are commonly found within a multitude of industrial and switchgear applications, electrical equipment, wiring systems and circuit breakers. This fuse range is suitable for general purpose use.
Features & Benefits
The low-temperature rise enables the fuse to be suitable for high-density mounting
Fuse links, specifically designed for the protection of equipment
Conforms to industry standards
Low voltage fuse
High rupture capacity (HRC)
Suitable for three-phase applications
Suitable for type 2 co-ordinated applications as defined in IEC 947-4
Low power loss, typically 20% lower than the requirements of BS 88
Fuse links, specifically designed for the protection of equipment
Conforms to industry standards
Low voltage fuse
High rupture capacity (HRC)
Suitable for three-phase applications
Suitable for type 2 co-ordinated applications as defined in IEC 947-4
Low power loss, typically 20% lower than the requirements of BS 88
Why use a slotted tag fuse?
A slotted tag fuse is distinguished by the metal slotted tags that extend off the ends of the fuse. This tag can either enable the fuse to have an offset tag or be centred to the fuse. Predominantly, this type of fuse is used within installations as a "weak link". They are designed to break when a fault occurs, such as an overcurrent or short circuit - they are a safety and damage protection measure within electrical circuits.
Eaton British Standard Fuse, 12A, 550V AC AAO16
Choose this fuse from Eaton to protect low-voltage equipment and machinery from the unsafe effects of overcurrent and short circuits. It acts as a 'weak link' and blows when a fault occurs to reduce the risk of damage to components. The fuse is easy to install using the mounting brackets on either end. It offers consistently reliable service throughout its lifespan so there's no need to maintain it. A robust design means the device is well-suited to industrial use as it resists contamination from outside elements. You'll find fuses like this in 3-phase automotive manufacturing and switchgear applications.
High breaking capacity of 80kA (kiloampere) for improved electrical safety
Clears high as well as low circuit faults
Low power loss for improved efficiency
Suitable for high-density mounting, thanks to its low temperature rise
Compact design for improved packing efficiency with dimensions of 85 (L) x 35.5 (H) x 13.7mm (D)
Clears high as well as low circuit faults
Low power loss for improved efficiency
Suitable for high-density mounting, thanks to its low temperature rise
Compact design for improved packing efficiency with dimensions of 85 (L) x 35.5 (H) x 13.7mm (D)
What causes a fuse to blow?
A fuse commonly blows as a result of circuit overload, when too much power is being drawn from an electrical supply. It can also blow as a result of a short circuit due to damaged wiring or moisture.
Note
Eaton formerly known as Bussmann
Specifikationer
Attribute | Value |
---|---|
Current Rating | 16A |
Fuse Size | A2 |
Voltage Rating | 550V ac |
Fuse Standard | BS88, IEC 60269 |
Fixing Centres | 73mm |
Application Category | gG |
Tag Width | 8.7mm |
High Rupture Capacity | Yes |
Overall Length | 85mm |
Body Diameter | 13.7mm |
Tag Type | Bolted |
Body Length | 35.5mm |
Tag Orientation | Offset |
Body Height | 35.5mm |
Fuse Dimensions | 13.7 x 35.5mm |
Series | Bussmann |