RCD Testers

An RCD (Residual Current Device) is a protective device that instantly breaks an electric circuit to prevent series harm from an ongoing electric shock. In the case of a single-phase circuit, the device monitors the difference in currents between the line and neutral conductors. This life-saving device, designed to prevent you from getting a fatal electric shock if you touch something live, (e.g. bare wire), offers a level of personal protection that ordinary fuses and circuit-breakers cannot provide.
RCD, is a generic term applied to a family of products which open automatically in response to a residual current equal to or greater than the RCD’s rated residual operating current. This generic term is often applied to the following:
RCCB - Residual Current Circuit Breaker
RCBO - Residual Current Breaker with Overcurrent protection
SRCD - Socket outlet RCD
PRCD - Portable Residual Current Device
An RCCB differs from an RCBO in that the RCBO will additionally respond to overcurrent conditions whereas the RCCB will not respond to such conditions. The term SRCD is applicable to an RCD which is an integral part of a socket outlet or which is fitted in a box immediately adjacent to a socket outlet.
RCD Technology
RCDs may be distinguished by their technology:-
Voltage Independent RCDs (VI). These RCDs rely on the energy of the residual current to activate the RCD. These devices are sometimes referred to as Electromechanical RCDs, and are voltage-independent in operation.
Voltage Dependent RCDs (VD). These RCDs use the mains supply voltage to power an electronic circuit and the tripping mechanism to activate the RCD. These devices are sometimes referred to as Electronic RCDs and are voltage-dependent in operation.
How do they work?
Under normal circumstances, the current flowing in the two wires is equal. When an earth leakage occurs due to a fault in the circuit or an accident with the equipment, an imbalance occurs and this is detected by the RCD, which automatically cuts off the power before injury or damage can result.
RCDs protect humans against electrocution in a way that fuses and circuit breakers do not. If you have a new circuit installed, or a circuit is substantially modified, you may be required to have an RCD fitted under the Building Regulations (Part P) or BS7671 wiring regulations. This is a legal requirement.
Using the wrong type of RCD can result in total loss of protection. RCD testers need to be tested every 12 months so any problems can be identified before they result in injury or equipment failure.

...
Read more Read less

Filter

Visar 1 - 11 av 11 produkter
Resultat per sida
Beskrivning Pris RCD Test Current RCD Test Type Display Type Safety Category Battery Type Calibrated Battery Life Power Source Dimensions Weight Height Length Maximum Operating Temperature Minimum Operating Temperature
RS-artikelnummer 123-2363
VarumärkeRS PRO
2 213,00 kr
Each
Enheter
10 mA, 20 mA, 30 mA, 100 mA, 300 mA, 500 mA AC LCD - - RSCAL - Mains 180 x 130 x 70mm 800g 70mm 180mm +40°C 0°C
RS-artikelnummer 123-2240
VarumärkeRS PRO
1 687,00 kr
Each
Enheter
10 mA, 20 mA, 30 mA, 100 mA, 300 mA, 500 mA AC LCD - - - - Mains 180 x 130 x 70mm 800g 70mm 180mm +40°C 0°C
RS-artikelnummer 123-2364
VarumärkeRS PRO
2 428,00 kr
Each
Enheter
10 mA, 20 mA, 30 mA, 100 mA, 300 mA, 500 mA AC LCD - - UKAS - Mains 180 x 130 x 70mm 800g 70mm 180mm +40°C 0°C
RS-artikelnummer 711-9003
Tillv. art.nrRCDT310
VarumärkeMegger
5 807,60 kr
Each
Enheter
500mA AC Selective, DC Selective LCD CAT III 300 V Rechargeable NiCd, Rechargeable NiMH UKAS 2000 Tests Battery 203 x 148 x 78mm 980g 78mm 203mm +40°C -5°C
RS-artikelnummer 711-9007
Tillv. art.nrRCDT310
VarumärkeMegger
5 592,60 kr
Each
Enheter
500mA AC Selective, DC Selective LCD CAT III 300 V Rechargeable NiCd, Rechargeable NiMH RSCAL 2000 Tests Battery 203 x 148 x 78mm 980g 78mm 203mm +40°C -5°C
RS-artikelnummer 712-5737
Tillv. art.nrRCDT310-EN-BS
VarumärkeMegger
5 066,60 kr
Each
Enheter
500mA AC Selective, DC Selective LCD CAT III 300 V Rechargeable NiCd, Rechargeable NiMH - 2000 Tests Battery 203 x 148 x 78mm 980g 78mm 203mm +40°C -5°C
RS-artikelnummer 537-7888
Tillv. art.nrRCDT320-FR
VarumärkeMegger
6 232,00 kr
Each
Enheter
1000mA DC LCD CAT III 300 V Rechargeable NiCd, Rechargeable NiMH - 2000 Tests Battery 203 x 148 x 78mm 980g 78mm 203mm +40°C -5°C
RS-artikelnummer 712-5746
Tillv. art.nrRCDT320-EN-BS
VarumärkeMegger
5 817,90 kr
Each
Enheter
1000mA DC LCD CAT III 300 V Rechargeable NiCd, Rechargeable NiMH - 2000 Tests Battery 203 x 148 x 78mm 980g 78mm 203mm +40°C -5°C
RS-artikelnummer 507-5661
Tillv. art.nrP01191511
VarumärkeChauvin Arnoux
7 124,26 kr
Each
Enheter
650mA AC - CAT III 600 V - - 2000 tests Battery 270 x 250 x 180mm 900g 180mm 270mm - -
RS-artikelnummer 711-9019
Tillv. art.nrRCDT320
VarumärkeMegger
6 368,10 kr
Each
Enheter
1000mA DC LCD CAT III 300 V Rechargeable NiCd, Rechargeable NiMH RSCAL 2000 Tests Battery 203 x 148 x 78mm 980g 78mm 203mm +40°C -5°C
RS-artikelnummer 711-9016
Tillv. art.nrRCDT320
VarumärkeMegger
6 583,10 kr
Each
Enheter
1000mA DC LCD CAT III 300 V Rechargeable NiCd, Rechargeable NiMH UKAS 2000 Tests Battery 203 x 148 x 78mm 980g 78mm 203mm +40°C -5°C
Relaterte Produkter
All instruments meet IEC1010, HD384 and BSEN61557, and ...
Description:
All instruments meet IEC1010, HD384 and BSEN61557, and are sealed to IP54 for weatherproof performance.Easy to hold and comfortable to use, the large display provides the unique combination of two digital readouts and an analogue arc.All primary results are displayed ...
Measurement of loop resistanceMeasurement of internal network resistanceMeasurement ...
Description:
Measurement of loop resistanceMeasurement of internal network resistanceMeasurement of short circuit currentLow resistance and continuity measurementInsulation testRCD/FI measurement (contact voltage, trip time, trip current - increasing current)Voltage and frequency measurementProduct informationMemory for ...
A range of insulation testers that meet the ...
Description:
A range of insulation testers that meet the relevant requirements of EN61557, BS7671, HD 384, IEC 364 and VDE 0413 for applications in all aspects of electrical contracting, building maintenance, testing, inspection and servicing. 20mm LCD display with true analogue ...
The GPT-900 series is built upon a platform ...
Description:
The GPT-900 series is built upon a platform of AC 500 VA maximum power output. The high efficiency PWM amplifier is the core of GPT-9900 platform, designed to impede the influence from the voltage fluctuation of input AC source. Output ...