Air Quality Sensors

Air quality sensors also known as air pollution sensors can detect and monitor air contaminants in the air around us. These sensors can be used inside to detect indoor air pollution and outside to monitor toxins and pollution in the air. They are able to detect dangerous gases which are toxic to humans and animals and can cause respiratory problems if inhaled or absorbed through the skin.


These sensors are small and portable and provide data in near-real time at low cost and using low amounts of power. Sensor based measurement devices are becoming more popular as people are more aware of harmful gases and pollutants and the health impacts this has on individuals and the environment.


The sensor measures and monitors the concentration of certain hazardous gases that are found in the air. If the gases detected are above a certain level which the sensor is set, the device or instrument will then trigger an alarm to warn people to leave the area.


These low-cost pollution sensors are used to gather data about the effects of traffic and factory work on air quality. They can also be used to help keep home environments safe and clean by monitoring indoor air quality levels of airborne particulates, humidity and temperature making you aware of areas with low ventilation.


What do air quality sensors measure?


They are used to detect, measure and monitor relative humidity, ambient temperature and / or levels of carbon dioxide (CO2), volatile organic compounds (VOCs), formaldehyde (HCHO), freon and other refrigerants (CFC / HFC), phosphine (PH3), hydrogen sulphide (H2S), carbon monoxide (CO), nitrogen dioxide (NO2), oxygen (O2), ozone (O3) and other flammable, hazardous or toxic gases.


...
Read more Read less

Filter

Visar 1 - 20 av 40 produkter
Resultat per sida
Beskrivning Pris Gases Detected Accuracy Meter Type Power Source Dimensions Weight Height Length Maximum Operating Temperature Minimum Operating Temperature Width
RS-artikelnummer 134-6643
Tillv. art.nrTGS2611-C00
VarumärkeFigaro
225,93 kr
Each
Enheter
Methane - - - 9.2 (Dia.) x 7.8mm 1.2g 7.8mm - - - 9.2 (Dia.)mm
RS-artikelnummer 134-6657
Tillv. art.nrLPM2610-D09
VarumärkeFigaro
170,32 kr
Each
Enheter
Butane, Propane - - - 27 x 12.5 x 14.1mm 2.8g 14.1mm 27mm +40 °C 0 °C 12.5mm
RS-artikelnummer 134-6658
Tillv. art.nrTGS2620-C00
VarumärkeFigaro
225,93 kr
Each
Enheter
Organic Vapour - - - 9.2 (Dia.) x 7.8mm 1.2g 7.8mm - - - 9.2 (Dia.)mm
RS-artikelnummer 173-0309
Tillv. art.nrIAQ-CORE P
Varumärkeams
284,394 kr
Each (In a Tray of 90)
Enheter
- - - - 15.2 x 17.8 x 4.3mm - 4.3mm 15.2mm +50 °C 0 °C 17.8mm
RS-artikelnummer 134-6660
Tillv. art.nrTGS6812-D00
VarumärkeFigaro
358,59 kr
Each
Enheter
Hydrogen, Methane - - - 12 (Dia.) x 13mm 1.5g 13mm - +70 °C -10 °C 12 (Dia.)mm
RS-artikelnummer 134-6640
Tillv. art.nrTGS2610-C00
VarumärkeFigaro
225,93 kr
Each
Enheter
Butane, Propane - - - 9.2 (Dia.) x 7.8mm 1.2g 7.8mm - - - 9.2 (Dia.)mm
RS-artikelnummer 134-6673
Tillv. art.nrTGS822-A00
VarumärkeFigaro
225,93 kr
Each
Enheter
Organic Vapour - - - 17 (Dia.) x 10mm - 10mm - - - 17 (Dia.)mm
RS-artikelnummer 134-6646
Tillv. art.nrFECS43-20
VarumärkeFigaro
2 202,73 kr
Each
Enheter
Sulphur Dioxide - - - 20.4 (Dia.) x 16.5mm 4.5g 16.5mm - +50 °C -30 °C 20.4 (Dia.)mm
RS-artikelnummer 134-6669
Tillv. art.nrTGS2600-B00
VarumärkeFigaro
182,60 kr
Each
Enheter
Air Contaminants - - - 9.2 (Dia.) x 7.8mm 1.1g 7.8mm - - - 9.2 (Dia.)mm
RS-artikelnummer 134-6648
Tillv. art.nrFECS44-100
VarumärkeFigaro
2 394,54 kr
Each
Enheter
Ammonia - - - 20.4 (Dia.) x 16.5mm 4.5g 16.5mm - +50 °C -30 °C 20.4 (Dia.)mm
RS-artikelnummer 134-6659
Tillv. art.nrTGS832-F01
VarumärkeFigaro
468,09 kr
Each
Enheter
CFC - - - 24 (Dia.) x 24.3mm 8.8g 24.3mm - - - 24 (Dia.)mm
RS-artikelnummer 134-6674
Tillv. art.nrFECS41-250
VarumärkeFigaro
2 011,13 kr
Each
Enheter
Nitric Oxide - - - 20.4 (Dia.) x 16.5mm 4.5g 16.5mm - +50 °C -20 °C 20.4 (Dia.)mm
RS-artikelnummer 134-6678
Tillv. art.nrTGS816-A00
VarumärkeFigaro
637,55 kr
Each
Enheter
Butane, Methane, Propane - - - 19.5 (Dia.) x 13.5mm 7.7g 13.5mm - - - 19.5 (Dia.)mm
RS-artikelnummer 134-6647
Tillv. art.nrTGS2611-E00
VarumärkeFigaro
159,07 kr
Each
Enheter
Methane - - - 9.2 (Dia.) x 12.4mm 1.4g 12.4mm - - - 9.2 (Dia.)mm
RS-artikelnummer 102-4162
Tillv. art.nrIAQ-CORE C
Varumärkeams
343,39 kr
Each
Enheter
- - - - 15.2 x 17.8 x 4.3mm - 4.3mm 15.2mm +50 °C 0 °C 17.8mm
RS-artikelnummer 134-6661
Tillv. art.nrNGM2611-E13
VarumärkeFigaro
171,44 kr
Each
Enheter
Methane - - - 27 x 12.5 x 14.1mm 2.8g 14.1mm 27mm +40 °C 0 °C 12.5mm
RS-artikelnummer 134-6677
Tillv. art.nrFECS42-20
VarumärkeFigaro
2 011,13 kr
Each
Enheter
Nitrogen Dioxide - - - 20.4 (Dia.) x 16.5mm 4.5g 16.5mm - +50 °C -20 °C 20.4 (Dia.)mm
RS-artikelnummer 134-6641
Tillv. art.nrTGS2610-D00
VarumärkeFigaro
232,55 kr
Each
Enheter
Butane, Propane - - - 9.2 (Dia.) x 12.4mm 1.4g 12.4mm - - - 9.2 (Dia.)mm
RS-artikelnummer 134-6642
Tillv. art.nrTGS5042-A00
VarumärkeFigaro
252,30 kr
Each
Enheter
Carbon Monoxide - - - 14.1 (Dia.) x 50.2mm 12g 50.2mm - +50 (Continuous) °C, +55 (Intermitter) °C -5 (Intermitter) °C, 0 (Continuous) °C 14.1 (Dia.)mm
RS-artikelnummer 134-6644
Tillv. art.nrTGS5042-B00
VarumärkeFigaro
302,13 kr
Each
Enheter
Carbon Monoxide - - - 14.1 (Dia.) x 50.2mm 12g 50.2mm - +50 (Continuous) °C, +55 (Intermitter) °C -5 (Intermitter) °C, 0 (Continuous) °C 14.1 (Dia.)mm
Relaterte Produkter
The iAQ-Core is a compact module for determining ...
Description:
The iAQ-Core is a compact module for determining indoor air quality. The MEMS technology sensor measures a broad range of VOCs (Volatile Organic Compounds) yielding a Total Volatile Organic Compound (TVOC) reading. Output: 450 to 2000ppm CO2 equivalent and 125 ...
The Sensirion SDP800 series of Analog differential pressure ...
Description:
The Sensirion SDP800 series of Analog differential pressure sensors offer superb performance and are targeted at high-volume applications. These sensors are for use with air or other non-aggressive gases and deliver accurate and stable results covering a range of up ...
The Sensirion SDP800 series of Digital differential pressure ...
Description:
The Sensirion SDP800 series of Digital differential pressure sensors offer superb performance and are targeted at high-volume applications. These sensors are for use with air or other non-aggressive gases and deliver accurate and stable results covering a range of up ...
SGPC3 is a digital low-power gas sensor designed ...
Description:
SGPC3 is a digital low-power gas sensor designed for indoor air quality applications. Sensirion’s CMOSens® technology offers a complete sensor system on a single chip featuring a digital I2C interface and a temperature controlled micro hotplate and a preprocessed indoor ...