Current Transducers

Current transducers, or current sensors, are an electrical component that detects electric current in a wire and converts it into another type of electrical signal proportional to the current value. The generated signal could be analogue voltage, current or a digital output. This generated signal can be then used to display the measured current in an ammeter, or can be used for the purpose of controlling other circuits. Current Transducer Types Current sensors can be either open-loop or closed-loop. •Open-Loop Sensor: This type measures AC and DC currents and provides electrical isolation between the circuit being measured and the output of the sensor. Open-loop current sensors are generally preferred in battery-powered circuits. •Closed-Loop Sensor: The Closed-Loop sensor is sometimes called a ‘Zero-Flux’ sensor because it features a Hall-Effect sensor that feeds back an opposing current into a secondary coil, wound on the magnetic core to zero the flux produced in the magnetic core by the primary current. Closed-loop sensors are often used when high accuracy is essential.

...
Read more Read less

Filter

Visar 21 - 40 av 315 produkter
Resultat per sida
Beskrivning Pris Input Current Range Sensor Technology Nominal Current Output Current Range Supply Voltage Transformer Type Maximum Cable Diameter Sensor Type Mounting Type Frequency Bandwidth Accuracy Bore Size Minimum Operating Temperature Series
RS-artikelnummer 731-5267
Tillv. art.nrHTA 200-S
VarumärkeLEM
573,51 kr
Each
Enheter
- Open Loop 200A - ±15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 32mm -25°C HTA
RS-artikelnummer 301-9495
Tillv. art.nrHAS 100S
VarumärkeLEM
241,85 kr
Each
Enheter
- Open Loop ±300A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 20.4 x 10.4mm -10°C HAS
RS-artikelnummer 207-2877
Tillv. art.nrHTA 100-S
VarumärkeLEM
583,49 kr
Each
Enheter
- Open Loop ±300A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 32mm -25°C HTA
RS-artikelnummer 452-9476
Tillv. art.nrDK 300 B10
VarumärkeLEM
3 578,67 kr
Each
Enheter
- - 300A - 20 → 50 V dc, 22 → 38 V ac - - - Panel Mount - ±1 % 21.7mm -20°C DK
RS-artikelnummer 499-5378
Tillv. art.nrLTSR 25-NP
VarumärkeLEM
162,13 kr
Each
Enheter
- Closed Loop 0 → ±80A - 5 V - - Hall Effect PCB Mount DC 100 to 200 kHz ±0.2 % 3.2mm -40°C LTSR
RS-artikelnummer 499-5536
Tillv. art.nrAP 50 B10
VarumärkeLEM
1 129,14 kr
Each
Enheter
- Closed Loop 50A - 24 V dc - - - DIN Rail 30 → 2000 Hz ±1 % 18mm -20°C AP
RS-artikelnummer 301-9502
Tillv. art.nrHAS 200S
VarumärkeLEM
241,85 kr
Each
Enheter
- Open Loop ±600A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 20.4 x 10.4mm -10°C HAS
RS-artikelnummer 446-0557
Tillv. art.nrAKR 200 C420L
VarumärkeLEM
3 220,81 kr
Each
Enheter
- - 200A 4 → 20mA 24 V dc, 150 V ac - - - Panel Mount 10 → 400 Hz ±1 % 19mm -20°C AKR
RS-artikelnummer 452-9325
Tillv. art.nrDK 400 B10
VarumärkeLEM
3 578,67 kr
Each
Enheter
- - 400A - 20 → 50 V dc, 22 → 38 V ac - - - Panel Mount - ±1 % 21.7mm -20°C DK
RS-artikelnummer 446-0614
Tillv. art.nrDK 100 B420
VarumärkeLEM
4 117,08 kr
Each
Enheter
- Open Loop 100A 4 → 20mA 20 → 50 V dc - - Hall Effect Panel Mount - ±2 % 21.7mm -20°C DK
RS-artikelnummer 180-7357
Tillv. art.nrLA 55-P
VarumärkeLEM
225,35 kr
Each
Enheter
- Closed Loop 0 → 70A 50mArms 12 → 15 V - - Hall Effect PCB Mount DC to 200 kHz ±0.9 % - -40°C LA
RS-artikelnummer 451-1396
Tillv. art.nrLF 1005S
VarumärkeLEM
1 943,92 kr
Each
Enheter
- Closed Loop 0 → 1500A 200mArms 15 → 24 V - - Hall Effect Panel Mount DC to 150 kHz ±0.4 % 40.5mm -40°C LF
RS-artikelnummer 169-7653
Tillv. art.nrCSNA111
VarumärkeHoneywell
303,672 kr
Each (In a Box of 30)
Enheter
- Closed Loop -60 → +60 mA -70 → +70A ±15 V - - - PCB Mount DC to 150 kHz ±0.5 % - 0°C CSN
RS-artikelnummer 446-0591
Tillv. art.nrDK 100 B10
VarumärkeLEM
3 668,84 kr
Each
Enheter
- Open Loop 100A - 20 → 50 V dc - - Hall Effect Panel Mount - ±2 % 21.7mm -20°C DK
RS-artikelnummer 446-0440
Tillv. art.nrAK 5 B420L
VarumärkeLEM
3 220,81 kr
Each
Enheter
- - 5A 4 → 20mA 24 V dc, 150 V ac - - - Panel Mount 20 → 100 Hz ±1 % 21.7mm -20°C AK
RS-artikelnummer 121-8175
Tillv. art.nrCSNA111
VarumärkeHoneywell
408,12 kr
Each
Enheter
- Closed Loop -60 → +60 mA -70 → +70A ±15 V - - - PCB Mount DC to 150 kHz ±0.5 % - 0°C CSN
RS-artikelnummer 527-8466
Tillv. art.nrDHR 100 C420
VarumärkeLEM
2 063,27 kr
Each
Enheter
- Open Loop 100A 4 → 20mA 20 → 50 V dc - - Hall Effect Panel Mount DC 20 to 6000 Hz ±1 % 32mm -40°C DHR
RS-artikelnummer 446-0541
Tillv. art.nrAKR 50 C420L
VarumärkeLEM
3 220,81 kr
Each
Enheter
- - 50A 4 → 20mA 24 V dc, 150 V ac - - - Panel Mount 10 → 400 Hz ±1 % 19mm -20°C AKR
RS-artikelnummer 188-3783
Tillv. art.nrLA 125P
VarumärkeLEM
392,71 kr
Each
Enheter
- Closed Loop 0 → 200A 125mArms 12 → 15 V - - Hall Effect PCB Mount DC to 100 kHz ±0.8 % 13 x 11mm -40°C LA
RS-artikelnummer 497-249
Tillv. art.nrCT 0.1P
VarumärkeLEM
721,32 kr
Each
Enheter
- - ±200 mA - 15 V - - Fluxgate PCB Mount 40 → 7000 Hz ±1 % 11mm -20°C CT
Related Products
Opening-type current sensors for electronic measurement of alternating ...
Description:
Opening-type current sensors for electronic measurement of alternating current.Galvanic insulation between primary and secondary circuits.8 mm maximum conductor diameter for TT 50-SD model and 16 mm for TT100-SD model.1 metre length pre-stripped cable.Applications: measurement of active power and calculation of ...
Linear current sensors from Honeywell incorporating LOHET II ...
Description:
Linear current sensors from Honeywell incorporating LOHET II Hall effect transducers. These devices have increased temperature stability and 10 times less temperature drift than the LOHET I types and produce a ratiometric output voltage that varies from 19% to 81% ...
ATO series is a split core current transformer ...
Description:
ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement).ATO series is an ideal current transformer for new Smart-Grid applications. Split-core ...
Flexible alternative to the current shunt or transformers ...
Description:
Flexible alternative to the current shunt or transformers for the isolated measurement of a.c. or d.c. currents. Both types have plastic Bayblend KU1468 UL94-VO cases.,High current types have current sensors based on the hall effect and null balance method. The ...