Current Transducers

Current transducers, or current sensors, are an electrical component that detects electric current in a wire and converts it into another type of electrical signal proportional to the current value. The generated signal could be analogue voltage, current or a digital output. This generated signal can be then used to display the measured current in an ammeter, or can be used for the purpose of controlling other circuits.

Current Transducer Types

Current sensors can be either open-loop or closed-loop.
•Open-Loop Sensor: This type measures AC and DC currents and provides electrical isolation between the circuit being measured and the output of the sensor. Open-loop current sensors are generally preferred in battery-powered circuits.


•Closed-Loop Sensor: The Closed-Loop sensor is sometimes called a ’Zero-Flux’ sensor because it features a Hall-Effect sensor that feeds back an opposing current into a secondary coil, wound on the magnetic core to zero the flux produced in the magnetic core by the primary current. Closed-loop sensors are often used when high accuracy is essential.

...
Read more Read less

Filter

Visar 1 - 20 av 356 produkter
Resultat per sida
Beskrivning Pris Input Current Range Sensor Technology Nominal Current Output Current Range Supply Voltage Transformer Type Maximum Cable Diameter Sensor Type Mounting Type Frequency Bandwidth Accuracy Bore Size Minimum Operating Temperature Series
RS-artikelnummer 793-4593
Tillv. art.nrHLSR 50-P
VarumärkeLEM
73,06 kr
Each
Enheter
- Open Loop 125A 50A 4.5 → 5.5 V - - Hall Effect PCB Mount 400 kHz ±1 % - -40°C HLSR
RS-artikelnummer 198-813
Tillv. art.nrAT 5 B10
VarumärkeLEM
560,74 kr
Each
Enheter
- - 5A - - - - - Cable Tie 50/60 Hz ±1.5 % 16mm -20°C AT
RS-artikelnummer 527-8696
Tillv. art.nrDHR 400 C420
VarumärkeLEM
2 358,80 kr
Each
Enheter
- Open Loop 400A 4 → 20mA 20 → 50 V dc - - Hall Effect Panel Mount DC 20 to 6000 Hz ±1 % 32mm -40°C DHR
RS-artikelnummer 436-2330
Tillv. art.nrLTS 6NP
VarumärkeLEM
153,24 kr
Each
Enheter
- Closed Loop 0 → ±19.2A - 5 V - - Hall Effect PCB Mount DC 100 to 200 kHz ±0.2 % 3.2mm -40°C LTS
RS-artikelnummer 286-361
Tillv. art.nrLV 25-P
VarumärkeLEM
654,32 kr
Each
Enheter
- Closed Loop 0 → 14 25mA 12 → 15 V - - Hall Effect PCB Mount - ±0.9 % - 0°C LV
RS-artikelnummer 206-2404
Tillv. art.nrHAL 200-S
VarumärkeLEM
494,77 kr
Each
Enheter
- Open Loop ±600A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 20 x 15mm -25°C HAL
RS-artikelnummer 521-932
Tillv. art.nrHASS 300-S
VarumärkeLEM
169,99 kr
Each
Enheter
- Open Loop ±900A - 5 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 20.4 x 10.4mm -40°C HASS
RS-artikelnummer 198-778
Tillv. art.nrAT 20 B420L
VarumärkeLEM
720,90 kr
Each
Enheter
- - 20A 4 → 20mA 20 → 30 V dc - - - Cable Tie 50/60 Hz ±1.5 % 16mm -20°C AT
RS-artikelnummer 179-6667
Tillv. art.nrLA 100-P
VarumärkeLEM
273,91 kr
Each
Enheter
- Closed Loop 0 → 150A 50mArms 12 → 15 V - - Hall Effect PCB Mount DC to 200 kHz ±0.7 % 12.7 x 7mm -40°C LA
RS-artikelnummer 715-7989
Tillv. art.nr2308030
VarumärkePhoenix Contact
2 047,65 kr
Each
Enheter
- - 0 → 200A 4 → 20mA 20 → 30 V dc - - - DIN Rail 20 → 6000 Hz ±1 % 32mm -40°C MCR-SL-CUC-200-I
RS-artikelnummer 527-8523
Tillv. art.nrDHR 100 C10
VarumärkeLEM
2 063,27 kr
Each
Enheter
- Open Loop 100A - 20 → 50 V dc - - Hall Effect Panel Mount DC 20 to 6000 Hz ±1 % 32mm -40°C DHR
RS-artikelnummer 321-6315
Tillv. art.nrLTS 15NP
VarumärkeLEM
153,24 kr
Each
Enheter
- Closed Loop 0 → ±48A - 5 V - - Hall Effect PCB Mount DC 100 to 200 kHz ±0.2 % 3.2mm -40°C LTS
RS-artikelnummer 301-9473
Tillv. art.nrLTS 25NP
VarumärkeLEM
153,24 kr
Each
Enheter
- Closed Loop 0 → ±80A - 5 V - - Hall Effect PCB Mount DC 100 to 200 kHz ±0.2 % 3.2mm -40°C LTS
RS-artikelnummer 666-8182
Tillv. art.nrCASR 6-NP
VarumärkeLEM
136,86 kr
Each
Enheter
- Closed Loop 6A - 5.25 V - - - PCB Mount 200 → 300 kHz ±0.8 % - -40°C CASR
RS-artikelnummer 451-1403
Tillv. art.nrLF 2005S
VarumärkeLEM
3 887,32 kr
Each
Enheter
- Closed Loop 2000A 400mArms 15 → 24 V - - Hall Effect Panel Mount DC to 100 kHz ±0.3 % 60.5mm -40°C LF
RS-artikelnummer 497-198
Tillv. art.nrHASS 100-S
VarumärkeLEM
179,19 kr
Each
Enheter
- Open Loop ±300A - 5 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 20.4 x 10.4mm -40°C HASS
RS-artikelnummer 301-9495
Tillv. art.nrHAS 100S
VarumärkeLEM
241,85 kr
Each
Enheter
- Open Loop ±300A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 20.4 x 10.4mm -10°C HAS
RS-artikelnummer 731-5267
Tillv. art.nrHTA 200-S
VarumärkeLEM
573,51 kr
Each
Enheter
- Open Loop 200A - ±15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 32mm -25°C HTA
RS-artikelnummer 207-2877
Tillv. art.nrHTA 100-S
VarumärkeLEM
583,49 kr
Each
Enheter
- Open Loop ±300A - 15 V - - Hall Effect Panel Mount DC to 50 kHz ±1 % 32mm -25°C HTA
RS-artikelnummer 666-8176
Tillv. art.nrCAS 15-NP
VarumärkeLEM
128,98 kr
Each
Enheter
- Closed Loop 15A - 5.25 V - - - PCB Mount 200 → 300 kHz ±0.8 % - -40°C CAS
Related Products
Measurement of continuous, alternating, pulsed and mixed currentsGalvanically ...
Description:
Measurement of continuous, alternating, pulsed and mixed currentsGalvanically isolated between inputs and measuring circuitSelf extinguishing plastic housing UL 94–V0Operating temperature range -10 to +85°C.
Single-pole Hall effect current transducersMeasurement of inserted conductorVoltage ...
Description:
Single-pole Hall effect current transducersMeasurement of inserted conductorVoltage output, Vout = ±4VCapable of measuring complex signalsExcellent precision and good linearityLow temperature driftBody material Plastic; Polycarbonate PBTOperating Temperature Range -10 to +80°CSecondary connector: stock no. 543-7738.
Compact PCB mounting designEta technologyExternal reference input (Stock ...
Description:
Compact PCB mounting designEta technologyExternal reference input (Stock No. 435-8779)Very low temperature driftWide frequency responseHigh noise immunityCurrent overload capacityBody material plastic to UL94-V0.
A wide range of open loop current transducers ...
Description:
A wide range of open loop current transducers for the electronic measurement of current dc, ac, pulsed... with galvanic separation between the primary and the secondary circuit. Low power consumptionVoltage outputCompact design for through-hole PCB mountingFactory calibratedSingle supply + 5 ...